Setup standards and guidance

Solver-free separation example

Separation models assign named criteria to boundaries of a loaded model. This example renders an airfoil assignment without launching FlightStream. The boundary numbers are illustrative; use the IDs from your own mesh. delete_separations="all" erases existing assignments before creating the new ones. Omitting a family leaves it unchanged; an empty list is refused.

from pyflightstream.script import Script, helpers
from pyflightstream.script.solver_setup import AirfoilSeparation

script = Script(version="26.121")
helpers.solver_settings(
    script,
    delete_separations="all",
    airfoil_separation=[
        AirfoilSeparation(name="WING", boundaries=[1, 2], valarezo_criterion=True)
    ],
)
commands = script.render()
assert commands.index("DELETE_SEPARATION -1") < commands.index("CREATE_AIRFOIL_SEPARATION")
assert "CREATE_AIRFOIL_SEPARATION WING 2 ENABLE" in commands
print(commands)

name labels an assignment; boundaries selects surface IDs, and valarezo_criterion selects the airfoil criterion. Axial vortex, cylindrical bulk and Stratford bulk assignments have separate typed models. Rendering checks command availability for the selected build; it does not establish whether a separation model is physically appropriate for your flow.

Generate workspace standards

For Python scripts that supply generated input files, use Script.park_input_file with a relative path inside the point folder. Drives, rooted paths and parent traversal are refused. Different content cannot share a case-insensitive destination. Actuator, rotary-motion and blade-frame helpers validate references and labels before creating entities.

Generate the guide and standard setup library while planning:

pyfs-matrix plan matrix.fs --workspace . --fs-version 26.123 --setup-guidelines --setup-standards

Both flags work independently. Generation requires an explicit --fs-version so each availability statement names its target build. The files go to the plural inputs/setups directory. The guide is SETUP_GUIDELINES.md; s900 through s908 are scenario starting points and explicit study baselines. s910 through s956 vary one setting relative to the baseline named in that file: s900 for steady attached flow, s904 for unsteady controls, s905 for transonic refinement, or s906 for laminar-separation sensitivity. s929 is retired and not reused: every standard states farfield_layers = 5, and the setup model refuses a value outside the documented range 1 to 5. s947 is retired and not reused: thin boundaries are declared in the geometry's boundaries file. The matrix's SET column selects the setup identifier as usual.

The low-cost baseline assumes low-Mach attached flow and a fully turbulent boundary layer. The coupled, rotor and transonic examples require the corresponding physics and workflow. They are starting points for comparisons, not calibrated predictions or a promise that enabling more controls improves accuracy. Single-setting values are illustrative study choices. Boundary examples carry Wing and Body labels; replace those labels and illustrative diameters with your actual geometry before planning. Fields ending in _families use family selectors; the other boundary lists use declared boundary labels or one-based indices.

Each preset comments every typed setup key, the chosen override or omitted state, documented defaults and command evidence. The guide also inventories command arguments. A control unavailable in the target command database is commented UNAVAILABLE rather than emitted. Such a file is not a test of that control. Select an evidenced build or a supported model-assignment route. For example, newer builds select Valarezo within an airfoil separation assignment rather than through the legacy global toggle:

airfoil_separation = [{name = "Wing", boundaries = ["Wing"], valarezo_criterion = true}]

FlightStream 26.100 has no airfoil separation model (the command first appears in 26.101). On a 26.100 row, airfoil_separation is warned at plan and in post.log and skipped: the command is not emitted and the row runs with no separation model. The separation setting of that build is axial_separation_families (User Guide, Flow separation). The two models are different, and the package does not claim that they agree.

The separation declaration has two generations. On 26.100 and earlier, separation is declared by per-mechanism boundary lists: valarezo_separation_boundaries, crossflow_separation_boundaries and axial_separation_families. From 26.101 it is declared by named separation models: airfoil_separation, bulk_separation, axial_vortex_separation, cylindrical_bulk_separation and stratford_bulk_separation. A per-mechanism key is accepted only on a build whose command database row carries its command; on a later build it is refused at plan, naming the named-model keys.

The existing command database still refuses unsupported or broken emissions. Documented syntax, successful parsing, usable native operation and validated aerodynamics are different evidence claims. The generator executes no solver. The bibliography explains physical assumptions; it does not establish native command compatibility. Roughness is not simply an early transition trip, and a pressure-difference threshold calibrated at one Reynolds number, Mach number and geometry is not a universal stall model.

Generation reports created, unchanged, or preserved for each destination. Existing differing files, including user-owned s9XX collisions, are never overwritten. To compare a new package's definitions without disturbing edits, generate into a separate workspace and review the differences. Generation happens before normal matrix planning, so created files remain if a subsequent matrix check fails. Review the printed statuses and the normal plan result.

s907 combines viscous coupling and an airfoil-separation assignment. s908 combines laminar and airfoil separation as an explicit interaction hypothesis, not an established recommendation. Compare their separate effects first.

Inspect the resolved setup

pyfs-matrix inspect-setups MATRIX.fs --workspace CAMPAIGN --fs-version 26.124 prints complete per-row JSON: typed settings, whether each value came from the setup or a package default, row NCPUS overrides, command evidence, reference aliases and frames, custom flags, raw commands, and raw-mesh boundary conditions. The ordinary plan command prints a concise view from those same records and stores them under setup_inspections in post/<matrix>/plan.json. Point-dependent quantities and native defaults not established by evidence are not guessed.

Velocity, Mach and coefficient normalization

freestream_input = "velocity" preserves the normal velocity setter. Selecting freestream_input = "mach" instead emits SOLVER_SET_MACH_NUMBER using the Mach already resolved from the row's flight condition. It introduces no second Mach value in the setup. The inspection record includes this choice.

Mach mode requires the resolved velocity, Mach and sound speed to agree. On builds whose fluid command takes the heat-capacity ratio, the sound speed must also agree with sqrt(gamma * pressure / density) and the emitted temperature using the package's canonical dry-air gas constant. The native manual states that modern sonic velocity follows temperature and specific-heat ratio (26.120 User Guide, p.328). Missing fluid data, an inconsistent independent sound-speed pin, or a conflicting sonic override is refused before settings emission. Use velocity mode to preserve such independently specified states; switching the native setter must not change the physics.

Coefficient normalization is a separate choice: reference_velocity_m_per_s, reference_mach, or the explicit disable_reference_velocity = true reset. Only one may be stated. With none present, the existing freestream reference velocity remains explicit. On 26.124/build 8172026, the measured reset changed a held 47.513 m/s reference to the 30 m/s freestream and then followed a subsequent 40 m/s freestream change. The saved override flag changed from true to false.

The same build, at Mach 0.13, temperature 288.15 K and gamma 1.4, saved 44.2381515552 m/s through the Mach setter versus 44.2382184434 m/s through the velocity setter. The 1.51 ppm difference falls inside the 2 ppm acceptance bound for this control only. Mach and fluid inputs are not adjusted to hide native rounding, and this single measurement is no general precision guarantee.

Multiple actuator discs

Keep the existing flat ACTUATOR keys for one disc, or use ordered brace records in the existing free-variable cell:

ACTUATOR: {ACTUATOR: Left / ACTUATOR_RPM: 2000 / ACTUATOR_THRUST: 100}, {ACTUATOR: Right / ADVANCE_RATIO: 0.5 / ACTUATOR_THRUST: 200}

Each referenced actuator block may state thrust_units and wake_type; ACTUATOR_THRUST uses that block's thrust_units (default NEWTONS).

Each name selects its own reference actuator block. An advance ratio uses that block's diameter and the point velocity; RPM and loading belong to that record. PROFILE: <stem> selects a separate radial profile instead of net thrust, and requires the reference block's blade count. Every converted native profile is written and hashed. Do not mix brace records with flat actuator loading keys. Duplicate disc names and unknown record keys are refused. This syntax and its emission are checked offline; native multi-disc operation requires its own test.

The reference block may additionally choose wake_type = "RIGID" or "RELAXED". Omission preserves the native default. thrust_units selects NEWTONS (the existing default), POUNDS, or COEFFICIENT for that block's ACTUATOR_THRUST value; profile-file force units remain profile_units. The coefficient convention is native and must match the intended formulation; dimensional thrust avoids that ambiguity (FlightStream User Guide, p.187). These newly exposed variants require the separate native controls recorded by this release; their typed acceptance alone is not proof of a wake or load effect.

A setup can request explicit lifecycle actions after the row creates its discs:

[[actuator_operations]]
op = "rename"
actuator = "Left"
name = "LeftCruise"
[[actuator_operations]]
op = "enable"
actuator = "LeftCruise"

These tables belong at the root of an s<> setup. delete removes one named disc. Each action uses the name at that step, and deletion updates subsequent numbering. Unknown or ambiguous names and duplicate rename destinations are refused. A missing action never deletes or disables anything. disable is retained only on builds that document that command; current builds refuse it through the command registry. Saved actuators can be edited by these actions, but mixing new discs with a saved actuator inventory retains its existing explicit refusal.

Uniform inlet and outlet boundaries

Geometry, setup and conditions have separate owners. The geometry sidecar identifies the physical surfaces:

# inputs/geometries/duct/duct.boundaries.toml
boundaries = ["Inlet", "Outlet", "Wall"]
[import]
units = "METER"
[trailing_edges]
none = true
[ports]
feed = "Inlet"
exit = "Outlet"

The setup selects which geometric ports act as inlet or outlet:

# inputs/setups/s020.toml
apply_trailing_edges = true
apply_wake_termination = false
apply_base_regions = false
[[ports]]
port = "feed"
kind = "inlet"
velocity_variable = "FEED_VELOCITY"
# profile_variable = "FEED_PROFILE" # optional file selected by MATRIX
[[ports]]
port = "exit"
kind = "outlet"
velocity_variable = "EXIT_VELOCITY"

The row's MATRIX free cell supplies FEED_VELOCITY: -10 / EXIT_VELOCITY: 10. An omitted velocity_variable selects <PORT>_VELOCITY with the identity uppercased. An omitted profile_variable requests no profile. Selecting one requires that MATRIX variable to name a file under inputs/profiles/. No numeric condition or profile filename is copied into the geometry or setup. The offline suite checks the workspace example and emitted commands.

The surface names are exact after import renames. Velocity values are passed unchanged in simulation velocity units. The current manual is inconsistent: the command text describes signed normal velocity, but the GUI note on p.189 says direction follows the boundary type and signs are unnecessary. The negative inlet above is an explicit test input; the native control compares it with a positive inlet. Neither direction is claimed verified from parser acceptance. Setup array order is preserved across both port kinds. none = true excludes marking or detection and produces a no-wake warning; it cannot request wake termination nodes. The generator tests/tier3_licensed/duct.py reproduces the synthetic duct locally; its boundary controls remain in tests/tier3_licensed/inputs/duct. These are controlled test inputs, not a validated duct-flow result.

An inlet may select profile_variable = "FEED_PROFILE" in its setup and FEED_PROFILE: inlet-profile.txt in MATRIX. The reader hashes the file, building refuses later changes, and the run stages and hashes its exact bytes. FlightStream User Guide supplied with 26.123/26.124, printed/PDF p.190, defines comma-separated x,y,z,Vmag rows mapped to the inlet. No actuator-profile conversion is applied. The command uses the inlet sequence index, independently of the mesh boundary index. Native profile mapping and the velocity-sign discrepancy remain explicit acceptance checks.

The GUI discusses outlet profiles, but the scripting reference supplies no outlet-profile setter; a setup requesting one is refused by name. Port remeshing is explicit through [ports.remesh]; it runs after port creation and before profile assignment. On the measured 26.124 build, remeshing an outlet after an inlet requires its position in the combined created-port sequence. The paired native control increased the target cap from two to 28 triangles while retaining its area and the other boundaries. This establishes mesh editing, not a solved port flow. The GUI exhaust-outflow perimeter feature also lacks a proven scripted counterpart; SET_OUTLET_TRAILING_EDGES addresses base regions and is not substituted for it. See Boundary conditions and initialization actions for the available actions, ordering and current evidence limits.

ROTOR_SHEDDING is refused in matrix workflows because it has no effective native route there. CCS_SHEDDING controls the shedding digit on the CCS file-import route; it is not a general rotor wake-direction switch. The standalone Python component helper remains available.

Applying existing boundary declarations

The setup choices apply_trailing_edges, apply_wake_termination and apply_base_regions select application of the corresponding geometric declarations. false means do not redefine them; it never emits a delete or clears saved FSM state. true requires the corresponding declaration. Omitting a choice adapts the published TE/wake/base sidecar behavior, preserving existing workspaces. Explicit base-region editing actions conflict with apply_base_regions = false.

The unreleased sidecar [[inlets]] and [[outlets]] forms are rejected with a setup/MATRIX migration message. Use [ports] for identity only. Creating ports on a saved FSM remains refused while its existing port indices are unknown; use a fresh mesh for the measured creation sequence. No saved state is implicitly cleared.

Launch runtime resources

An optional setup block selects resources on the local solver machine:

[runtime]
max_threads = "auto"
affinity = "auto"

max_threads also accepts a positive integer. affinity = "all" disables pinning while retaining the selected thread count. Omitted fields remain unset; without [runtime], execution retains its existing behavior. Do not combine runtime.max_threads with the legacy max_threads or a row's NCPUS.

On hybrid Intel machines, auto selects P-core logical processors, including SMT, with KMP_HW_SUBSET="<Pcores>c:intel_core,<smt>t" and KMP_AFFINITY="granularity=fine,compact". Homogeneous single-socket machines use all logical processors without pinning. Multiple sockets or NUMA nodes select the lowest-numbered NUMA node and pin to its logical processor list. Affinity is applied only to the solver subprocess, retaining license and installation variables. Explicit affinity replaces inherited KMP affinity variables.

The homogeneous policies are inferred from GOAL-076, not measured. They are conservative starting points for the kit's calibration to confirm. Detection uses Windows processor relationships or Linux sysfs; unsupported or incomplete topology is refused. Submitted jobs cannot use the submit host as evidence for a compute node, so max_threads and affinity require a local launch on the solver machine; the concurrency keys below do not, and a submitted run ignores them.

A Python user builds the same settings through SolverSettings(runtime=...), which validates a mapping with the keys above and refuses an unknown key. The type behind it, RuntimeSettings, is not a public name: it is not in any module's __all__, and naming it public would put it in the pyflightstream.cases root, whose names are fixed. Build it from the mapping, as the setup block does:

from pyflightstream.cases import SolverSettings

solver = SolverSettings(runtime={"max_threads": 4, "parallel": 2})
assert solver.runtime.max_threads == 4

The run record's solver_setup.runtime stores the resolved count, requested affinity, applied KMP environment and topology (physical and logical cores, P/E classification, per-core SMT, sockets and NUMA membership).

Concurrent runs

The same block sets how many solver runs of one campaign are alive at once:

[runtime]
parallel = "auto"      # a positive count, or "auto"; unset is 1
licence_seats = 2      # seats this machine may use; unset is 2
ram_floor_gb = 1.0     # free memory a further run needs before it starts; unset is 1.0

Unset, the campaign runs its cases one after another, exactly as before. Each case (one row of the matrix, with all its points) is one unit of concurrency, so a matrix of a single row gains nothing. pyfs-matrix run --parallel N|auto overrides the block for one run. A count above 8 runs 8 and warns.

auto is the smallest of 2 (the measured optimum on a multi-core machine, which comes from the serial gaps of a run and not from free cores), licence_seats, the free memory divided by ram_floor_gb, and 8. The seat count is configured: the licence server is not queried. A further run starts only when fewer than the count are alive, the free memory is at least ram_floor_gb, and a few seconds have passed since the previous start, because a solver claims its memory as it loads; the first run always starts. A run that fails with the licence named in the solver's own output lowers the count to one and is repeated once, alone, with a warning that quotes the line taken for the refusal; every run refused while runs overlapped is repeated so, and a seat count set too high costs those repeats and no recorded failure. The licence wording is matched, as whole words, against the captured text and is not yet confirmed against a licensed probe; a failure it does not match is recorded as the run's failure and is not repeated.

Every case is staged before the first run starts; each run still writes only into its own datapoint folder, and manifest rows are appended under a lock, in the order the runs finish. A failed run does not stop the others; an interrupt (Ctrl-C) or an unexpected error starts no case still queued, and the runs alive end on their own. Simulations are posted after the last run ends, not as each finishes. Only local runs are concurrent: a submitting or grouping executor runs one at a time, with a note. A [runtime] block with only these keys resolves no thread count or affinity. Each concurrent run launches with the thread count and affinity of its own case.