Skip to content

Installed-frame copy

The installed-frame copy of a product table

pyflightstream.post.inflow_tools.to_installed_frame(table) writes <table>_installed.csv beside a product table stated in the ISOLATED frame, the same numbers in the INSTALLED frame, which is the isolated one mirrored through y = 0. It never overwrites; the isolated table is the record and this is a second table beside it, unless out= names another place for it, and flip= names further columns to negate. Applying it to its own output returns the input. A rotor table may open with one alias line that holds no comma; it is kept as it stands.

Blade and family names do not change. Blade k of the image wheel, at +(k - 1) 60 degrees on a six-blade wheel, is blade k of the installed wheel, at -(k - 1) 60, so a table keeps its row order and its names. The mirror changes sign or maps a column as this table says (a column name is matched case-insensitively at its start, then _, a digit or the end of the name; the code reads the same list, FLIPPED_COLUMNS and AZIMUTH_COLUMNS, and a test holds the two equal):

column treatment why
FY flip the force along the mirrored axis
MX flip a moment about an axis in the mirror plane
MZ flip a moment about an axis in the mirror plane
CY[A-Z]* flip the side-force coefficients
CR(?!EF)[A-Z]* flip the roll coefficients, a moment about x (never CREF, the reference chord)
CN[BSW]\d* flip the yaw coefficients of the body, stability and wind axes
CMX flip the coefficient of MX
CMZ flip the coefficient of MZ
TORQUE flip the sense of rotation reverses in the mirror
RPM flip the signed speed follows the sense of rotation
CQ flip the torque coefficient keeps the signed torque, so it flips with TORQUE
BETA flip the sideslip angle
CS flip the side-force coefficient
CMN flip the yawing-moment coefficient
Y flip a position along the mirrored axis: a point at +y appears at -y (class: position)
YMOM flip the y of the moment point, a position along the mirrored axis (class: position)
VY flip the y component of a velocity (class: polar vector)
VORTICITY_[XZ] flip the x and z components of a vorticity (class: axial vector)
AZIMUTH azimuth psi -> -psi mod 360
AZIMUTH_START azimuth psi -> -psi mod 360
AZIMUTH_END azimuth psi -> -psi mod 360
azimuth_deg azimuth psi -> -psi mod 360
H\d+_PHASE_DEG azimuth the phase of harmonic k in azimuth: cos(k psi - PHI_k) read at -psi is cos(k psi + PHI_k), so PHI_k -> -PHI_k mod 360
FX keep along the axis the mirror leaves
MY keep a moment about the normal of the mirror plane
CT keep the thrust coefficient
CP keep the power coefficient, CP = 2 pi CQ sign(RPM): CQ and RPM both flip
C_PHASE_DEG keep the phase of the Theodorsen function, a function of the reduced frequency alone
S_PHASE_DEG keep the phase of the Sears function, a function of the reduced frequency alone

Every other column ending in _PHASE_DEG maps by psi -> -psi mod 360, as the harmonic phases do. The Theodorsen and Sears phases C_PHASE_DEG and S_PHASE_DEG are functions of the reduced frequency, not of azimuth, and are kept. The sectional Fx, Fz and Moment are NOT negated by default: the orientation of the section axes is not settled, and negating them on a guess would write a wrong number that looks like a right one. The flip= argument names them once it is. Any other column is copied as written.

The post writes the copies of the inflow tables. [products] installed_frame in the pproc is a list of families from probes and inflow (default empty; any other name is refused when the pproc is read, naming these two). For probes the post writes probes/<point>_probes_installed.csv beside each probes table; for inflow it writes <stem>.inflow_installed.dat beside each reusable inflow profile (fields/<stem>.inflow.dat), the six columns x y z vx vy vz read as X Y Z VX VY VZ. Each copy is the mirror through y = 0 by the one classification above, so a probe at +y appears at -y, its VY changes sign and its vorticity's x and z components change sign, while every other column is copied as written. Mirroring a copy again returns the source.

The classes are three: a POSITION (Y) and a POLAR vector (a velocity VY, a force FY) change the sign of the y component; an AXIAL vector (a moment, a vorticity) changes the sign of its x and z components; an azimuth, and the phase of a harmonic in azimuth, maps psi -> -psi mod 360. A harmonic's mean and amplitude are copied as written, which holds for a quantity the mirror does not negate. A column the classification cannot place is copied unchanged and named once per simulation in post.log; the columns the probes table carries by construction (its spine, the condition and reference columns, the fluid parameters and the solver's own probe export) are placed and never named.

Each copy is listed in products.json with "kind": "installed_frame" and its source table in the entry's source field.

The copy is the isolated-frame table mirrored, blade k staying blade k. It holds where the installed configuration is the mirror image of the simulated one, and it asserts nothing about a flow that is not (a wake, a body or a rotor that is not mirror-symmetric).