Per-station harmonics
The per-station harmonics¶
Current behaviour
The 0P, 1P and 2P content of every blade station's load around the disc, from the sections the post already wrote.
reductions/<point>_harmonics.csv, one per rotor point that has samples at
several azimuths. For each rotor, each blade station and each sectional load
quantity of the sections export, the least-squares fit
load(psi) = H0 + A1 cos(psi - PHI1) + A2 cos(2 psi - PHI2)
over every sample of that station, psi being the sample's blade azimuth in
degrees.
It is read from the WRITTEN sections. The samples are the rows a user
holds, read back, and psi is the table's own AZIMUTH: no azimuth is
computed again. Which rows:
- a
qsteady_rotorWHEEL point: every blade at every clocking ofsections/<point>_sections.csv(CLOCKING), whoseAZIMUTHis each block's own blade at its clocking (The quasi-steady rotor). The wheel's premise is identical blades, so bladenat clockingiis one more azimuth of the same station: a wheel ofNblades atkclockings givesN ksamples,N kdistinct azimuths360 / (N k)apart. A sector point has one azimuth and no file. - an
unsteady_rotorpoint: every blade at every step of the LAST COMPLETE REVOLUTION of that rotor inseries/<point>_sections_series.csv, the per-step sectional exports. Revolutionmis stepsfirst + (m - 1) Ntofirst + m N - 1, counted from the series' first stamped step asper_revolutioncounts from its first row, withNthe rotor's ownsteps_per_revolutionfrom the run record as an integral number of steps. Fractional clocks are skipped by rotor inproducts.json, stating the clock and its fractional remainder; the steps after the last complete revolution are not read. The series states each block's OWN blade's azimuth (bladenof the rotor'sBat blade one's plus(n - 1) 360 / B, the blades placed ahead of blade one whatever the sense of rotation, as the per-blade table places them,pyflightstream.post.axes.placed_blade_azimuth_deg), and the fit reads it as stated. See the harmonics migration for older series.
A sample is a BLOCK of one blade: the consecutive rows of one clocking or
step whose FAMILY names families of one blade of the rotor, blade n being
the n-th entry of its families_blades (expanded through the aliases). A
block of several blades, or of a family no blade names, is not a sample.
Distinct distributions of one blade are not pooled, even in the same plane;
the rotor is skipped. A blade block with unavailable azimuth is omitted with
a note naming its sample. A station quantity without any finite sample is
registered as a skip with the rotor, station and quantity.
The stations. Station j is the j-th row of every blade block of the
rotor, at the radius from the hub of the first sample, as the validity
columns read it. For a rotor frame this is |Offset|; for an MRP cut it is
the absolute value of Offset - (hub - moment_point) along the cut normal. Where
the hub is off the cut's radial line, the recorded frame is ambiguous, or a
historical record lacks the moment point,
STATION_R_M and R_OVER_R read NA and post.log names the missing radius.
Every sample with a known radius must hold its station within a thousandth (1e-3) of the
first sample's largest radius: a station where one does not is left out and
named in products.json skipped under
reductions/<point>_harmonics.csv#rotor=<ALIAS>#station=<j>, and a rotor whose
blocks hold different numbers of stations, or which has no block of one blade
at a stated azimuth, under ...#rotor=<ALIAS>; each is a WARNING line in
post.log too, and the other stations are written.
The quantities. Every numeric load column of the export after the
condition: Fx, Fz and Moment of today's sectional loads export, each in
the export's own axes and units (N/m, N m/m). The station's place (Offset,
Chord, X_QC, Z_QC) and the columns the post adds (CLOCKING, K_1P,
the validity and the integrated strips) are not fitted. A harmonic of an
in-plane quantity describes the blade's load only where the export's axes
turn with the blade, as they do for a distribution cut in the blade's own
frame.
The columns. POL, the condition (CONTEXT_COLUMNS, the sections
table's own values), then
| column | what it is |
|---|---|
ROTOR |
the rotor's alias |
QUANTITY |
the export's column fitted |
STATION_R_M |
the station's radius, m |
R_OVER_R |
STATION_R_M over half the rotor block's diameter_m: the wheel's record's, and on an unsteady point the reference's the row names today; NA where no reference can be asked |
SAMPLES |
the samples fitted |
DISTINCT_AZIMUTHS |
how many distinct azimuths they hold, two within 1e-6 deg (360 and 0 included) being one |
H0 |
the mean, 0P |
H1_AMP, H1_PHASE_DEG |
A1 and PHI1 |
H2_AMP, H2_PHASE_DEG |
A2 and PHI2 |
RESIDUAL_RMS |
the root mean square of the samples less the fit made |
Amplitudes carry the quantity's unit. One row per rotor, quantity and station, in that order.
The phase convention. PHI_k is in degrees in [0, 360), in the
convention of the table's AZIMUTH (so on a left-hand rotor too): the kP
term peaks where k psi = PHI_k. The 1P term peaks at the azimuth PHI1;
the 2P term at the two azimuths PHI2 / 2 and PHI2 / 2 + 180. The fit is
H0 + a_k cos(k psi) + b_k sin(k psi) by numpy.linalg.lstsq, with
A_k = sqrt(a_k^2 + b_k^2) and PHI_k = atan2(b_k, a_k).
Too few azimuths is NA, said once. A fit up to kP has 2k + 1
unknowns, so 1P needs 3 distinct azimuths and 2P needs 5. A station with
fewer carries NA in that harmonic's amplitude and phase, and the fit is made
without it (H0 alone below 3); post.log carries ONE WARNING line per rotor
and harmonic that is NA anywhere, naming how many rows and the fewest
azimuths:
WARNING point=<point> product=reductions/<point>_harmonics.csv: rotor 'PROP': the 2P harmonic is NA in 9 row(s), whose stations hold as few as 4 distinct azimuth(s); a 2P fit needs 5
A wheel of 2 blades at 2 clockings (4 azimuths) has a 1P fit and no 2P. Nothing blocks: the table is written.
Azimuths that do not go round the circle are NA too, said once. Distinct
is not enough: samples crowded inside a half circle determine a sinusoid only
through differences at the round-off of their values, and five samples 0.1
deg apart on a constant load gave amplitudes of 1e5. The coverage criterion:
the kP term is fitted only where the angles k psi of the station's
samples, taken modulo 360, leave no gap larger than 180 deg around the
circle (the gap across zero included), and every lower term passes too, so a
station whose 1P angles fail has neither 1P nor 2P, and one whose 2P angles
fail keeps its 1P. It is checked for 1P, then 2P, after the count above; H0
is always fitted. Five samples inside a narrow sector fit H0 alone, while
samples at 0, 10, 180, 190 and 350 deg fit 1P but leave 2P NA. A harmonic
left out this way carries NA in its amplitude and phase, the fit is made
without it, HarmonicFit.reason states the first failed check (it is None
when both terms are fitted), RESIDUAL_RMS describes the reduced fit, and
post.log carries ONE WARNING line per rotor and harmonic, naming the number
of affected rows:
WARNING point=<point> product=reductions/<point>_harmonics.csv: rotor 'PROP': the 1P harmonic is NA in 9 row(s), whose samples do not go round the circle: a 1P fit needs the angles 1 psi with no gap over 180 deg
Samples evenly spaced round the whole circle, as a wheel's are, pass wherever they pass the count. The table is still written.
Not written, and said. An unsteady rotor whose record states no
steps_per_revolution, or whose series holds no complete revolution, is named
under reductions/<point>_harmonics.csv#rotor=<ALIAS>; where no station of any
rotor could be fitted the file is not written and products.json names it.
An unsteady rotor point that cuts sections (its record states a sections
layout) and has no sections series (its row exported no per-step sectional
loads, or the series was not written), no export window, or no rotor its
record states is named under reductions/<point>_harmonics.csv, with
a WARNING line in post.log.
The manifest. products.json registers the file with kind
harmonics, source wheel clockings or unsteady last revolution,
samples (the blade samples fitted, all rotors) and samples_by_rotor; a
wheel's entry adds clockings, an unsteady point's revolution (the first
and last step fitted, per rotor) and steps_per_revolution.