pyflightstream.workspace.naming (stable)¶
Generated from the docstrings at build time: every one of the 29 names in the __all__ of pyflightstream.workspace.naming has an entry below. The names a guide or an example uses come first; the others follow under Advanced.
Output-only naming templates for human-readable run file names.
Pipeline role: renders the human-readable names of generated scripts,
per-point exports, and simulation archives from a user-configurable
template. Names are a reading convenience for people and external
tools, nothing more: run identity lives in the campaign manifest
(runs.json), never in a file or folder name, and no API in this
package parses a generated name back into its parts (SAD Section 6).
Structural simulation and datapoint folders have explicit inverses below;
these do not parse configurable generated file names.
Available placeholders:
{campaign}: the campaign name.{sim}: thesim_idof the case.{point}: the point name of :func:pyflightstream.cases.point_name, every variable the row's flight condition declares, in its order, for exampleM144RE438AL+000BE+000J+080.{alpha},{beta}: sweep angles in deg, compact (2,-3.5).{advance_ratio}: rotor advance ratio J, dimensionless, compact.{mach}: free-stream Mach number of the case, compact.{polar}: the file stem of the point,P<sim>-<point name>, soP2001-M144RE438AL+000BE+000J+080(in legacy releases it wasPOLAR-<sim>_M<mach*100>AL..BE..J..).{name}, in OUTPUT names only: the rendered point stem, so every export hangs off the point's name whatever template produced it.
The default templates are {point} for per-point files and
sim_{sim} for archives; the matrix command line names points by
:data:MATRIX_POINT_NAME, P<sim>-<point name>. A workspace written
in legacy releases carries older names; see docs/upgrading.md for supported
workspace formats and explicit migration.
Advanced¶
pyflightstream.workspace.naming.ARCHIVE_STAMP_PATTERN
module-attribute
¶
ARCHIVE_STAMP_PATTERN = '\\d{8}-\\d{6}'
pyflightstream.workspace.naming.NamingTemplate
¶
Bases: BaseModel
User-configurable output names for scripts, exports, and archives.
The template is output only: it decorates files for human reading,
while run identity stays in the manifest. Configure it per
workspace by passing it to
:class:~pyflightstream.workspace.CampaignWorkspace.
Attributes:
| Name | Type | Description |
|---|---|---|
point_name |
str
|
Template of per-point file stems (generated scripts and
rendered export names). Default |
archive_name |
str
|
Template of simulation archive stems; only |
Examples:
>>> template = NamingTemplate()
>>> template.render_output("loads_{point}.txt", campaign="polar", sim="9001",
... point={"alpha": 2.0}, point_name="AL+020")
'loads_AL+020.txt'
render_point
¶
render_point(
*,
campaign: str,
sim: str,
point: dict[str, float],
mach: float | None = None,
advance_ratio: float | None = None,
name: str | None = None,
) -> str
Render the file stem of one sweep point.
Parameters:
| Name | Type | Description | Default |
|---|---|---|---|
campaign
|
str
|
Campaign name for |
required |
sim
|
str
|
Case |
required |
point
|
dict of str to float
|
Sweep point coordinates (alpha and beta in deg,
advance_ratio dimensionless), as produced by
:meth: |
required |
mach
|
float
|
Free-stream Mach number of the case for |
None
|
advance_ratio
|
float
|
The case's advance ratio for |
None
|
name
|
str
|
The point's name (:func: |
None
|
Returns:
| Type | Description |
|---|---|
str
|
The rendered stem, without extension. |
render_output
¶
render_output(
name: str,
*,
campaign: str,
sim: str,
point: dict[str, float],
mach: float | None = None,
advance_ratio: float | None = None,
stem: str | None = None,
point_name: str | None = None,
) -> str
Render the placeholders inside one declared output name.
A name without placeholders passes through unchanged, which
only a single-point case may declare: with placeholders (for
example "loads_{point}.txt") each point exports under a
unique name, and the campaign loop blocks a case whose points
would render the same name, because a later point of the same
simulation would otherwise overwrite an earlier export.
Parameters:
| Name | Type | Description | Default |
|---|---|---|---|
name
|
str
|
Declared output name, possibly holding placeholders. |
required |
campaign
|
str
|
Same meaning as in :meth: |
required |
sim
|
str
|
Same meaning as in :meth: |
required |
point
|
str
|
Same meaning as in :meth: |
required |
mach
|
str
|
Same meaning as in :meth: |
required |
stem
|
str
|
The point's rendered stem, for |
None
|
point_name
|
str
|
The point's name, for |
None
|
advance_ratio
|
float
|
The case's advance ratio for |
None
|
Returns:
| Type | Description |
|---|---|
str
|
The rendered output name. |
render_archive
¶
render_archive(
*, sim: str, campaign: str | None = None
) -> str
Render the archive file stem of one simulation.
Parameters:
| Name | Type | Description | Default |
|---|---|---|---|
sim
|
str
|
The |
required |
campaign
|
str
|
Campaign name for |
None
|
Returns:
| Type | Description |
|---|---|
str
|
The rendered stem; the workspace appends |
pyflightstream.workspace.naming.NamingTemplateError
¶
Bases: PyflightstreamError, ValueError
A naming template cannot be validated or rendered.
Raised when a template names an unknown placeholder, when a
placeholder has no value on the current point (for example
{mach} on a case without a Mach number), or when a rendered
name would not be a portable file name. The message lists what is
available, because a naming mistake must surface before any solver
run, not as a cryptic OS error mid-campaign.
pyflightstream.workspace.naming.PointName
¶
Bases: str
A point's name, as :func:pyflightstream.cases.point_name wrote it.
A str that has been CHECKED: not empty, a portable file name, and not
already carrying the DP- folder prefix. The datapoint folder is rendered
from it and never from a bare string, because a string that already held the
prefix, or a tag of the earlier scheme, put files in a folder the assessor
never looks in.
THE CALLER OF THE LEGACY NAMING SCHEME:
:func:datapoint_name_of builds one of these from a folder that ALREADY
EXISTS under a legacy tag, for a collector that read that folder off the
record rather than recomputing it. The harm above is a name INVENTED in the
old scheme, which files outputs where nothing looks; reading back a folder
that is already there is its opposite. That function answers None rather
than raising for anything it cannot check, which is what keeps this class's
refusal out of a caller that could not handle it.
Examples:
>>> PointName("M144AL+020")
'M144AL+020'
>>> try:
... PointName("a b")
... except ValueError as error:
... print(type(error).__name__)
NamingTemplateError
pyflightstream.workspace.naming.RunsManifestError
¶
Bases: PyflightstreamError, ValueError
A manifest name that does not name a file directly in the workspace root.
ValueError because the refused thing is the NAME a caller passed, before any file is read.
pyflightstream.workspace.naming.SIM_DATAPOINTS_DIR
module-attribute
¶
SIM_DATAPOINTS_DIR = 'datapoints'
pyflightstream.workspace.naming.archive_previous
¶
archive_previous(
base: Path, path: Path, *, matrix: str | None = None
) -> Path | None
Copy the file a writer is about to rewrite into the archive restore reads.
matrix names the folder under post/ for the kinds kept per matrix
(products.json, plan.json); a root kind (storage_management.json,
additional.json) leaves it None. Nothing is done when there is no
previous file. A copy that fails is warned and never raised: the writer goes
on, and the archive is a courtesy the write does not depend on. Returns the
copy, or None.
Parameters:
| Name | Type | Description | Default |
|---|---|---|---|
base
|
Path
|
The workspace root. |
required |
path
|
Path
|
The file about to be rewritten. |
required |
matrix
|
str
|
The matrix stem of a kind kept per matrix; None for a root kind. |
None
|
Returns:
| Type | Description |
|---|---|
Path or None
|
The archived copy, or None when there was nothing to copy or the copy failed. |
pyflightstream.workspace.naming.datapoint_dir_name
¶
datapoint_dir_name(name: PointName) -> str
Return the folder name one datapoint collects its outputs into (FR-92).
:data:DATAPOINT_PREFIX and the point name that already ends the
run_id and is the stem of every file of the point, so the folder, the
files and the run record carry ONE identity
(DP-M144RE438AL+000BE+000J+080).
Parameters:
| Name | Type | Description | Default |
|---|---|---|---|
name
|
PointName
|
The point's name, checked. |
required |
Returns:
| Type | Description |
|---|---|
str
|
Folder name, relative to :data: |
Raises:
| Type | Description |
|---|---|
NamingTemplateError
|
If |
pyflightstream.workspace.naming.datapoint_name_of
¶
datapoint_name_of(folder: str) -> PointName | None
Return the point a datapoint FOLDER belongs to, or None if it names none.
The inverse of :func:datapoint_dir_name, and it lives beside it because a
rule and its inverse drifting apart is the defect this module already
records for :data:ARCHIVE_STAMP.
Parameters:
| Name | Type | Description | Default |
|---|---|---|---|
folder
|
str
|
A folder name read off disk. |
required |
Returns:
| Type | Description |
|---|---|
PointName or None
|
The checked name, or None when |
The collector reads arbitrary folder names from disk. Returning ``None`` for a name that is
|
|
not a point folder lets it continue examining other folders and report the refusal in its
|
|
own vocabulary.
|
|
pyflightstream.workspace.naming.free_matrix_archive
¶
free_matrix_archive(
base: Path, stem: str, name: str, stamp: str
) -> Path
Return the free archive path of a matrix file: post/<stem>/archive/<stamp>/<name>.
Parameters:
| Name | Type | Description | Default |
|---|---|---|---|
base
|
Path
|
The workspace root. |
required |
stem
|
str
|
The matrix stem. |
required |
name
|
str
|
The file's name. |
required |
stamp
|
str
|
The archive stamp, :data: |
required |
Returns:
| Type | Description |
|---|---|
Path
|
A path no file holds yet; a second copy within one stamp goes under |
pyflightstream.workspace.naming.free_root_archive
¶
free_root_archive(
base: Path, name: str, stamp: str
) -> Path
Return the free archive path of a root file: archive/<stem>-<stamp>.json.
A second copy within one stamp is numbered .2, .3. This is the ONE
home of the spelling: run.records.restore reads what it names and every
writer of a restorable file archives through it.
Parameters:
| Name | Type | Description | Default |
|---|---|---|---|
base
|
Path
|
The workspace root. |
required |
name
|
str
|
The file's name; its stem names the copy. |
required |
stamp
|
str
|
The archive stamp, :data: |
required |
Returns:
| Type | Description |
|---|---|
Path
|
A path no file holds yet. |
pyflightstream.workspace.naming.group_token
¶
group_token(group: str | int) -> str
Return what a product file carries for one group: its NAME, or gNN.
The one place the two eras are told apart, so the rename that moves existing products and the stage that writes new ones cannot drift into two conventions -- which is the drift a technical-writing lens flagged, since the migration page's whole promise is that the renamed file IS the file the next post writes.
Parameters:
| Name | Type | Description | Default |
|---|---|---|---|
group
|
str or int
|
The polar group: its name, or its number in a product written before names. |
required |
Returns:
| Type | Description |
|---|---|
str
|
The name, or |
Raises:
| Type | Description |
|---|---|
ProductError
|
If the group has no name, or its name has the shape of the numbered tokens it would be confused with. |
pyflightstream.workspace.naming.is_portable_name
¶
is_portable_name(text: str) -> bool
Whether text is a plain file-name-safe token: no separators, no whitespace, not empty.
A name Windows reserves for a device (NUL, CON, COM1) is not a file name there
and is not portable either.
Parameters:
| Name | Type | Description | Default |
|---|---|---|---|
text
|
str
|
The candidate name. |
required |
Returns:
| Type | Description |
|---|---|
bool
|
True when the text is not empty and holds no separator, whitespace or reserved name. |
pyflightstream.workspace.naming.machine_description
¶
machine_description() -> str | None
Describe the machine this process runs on, without naming it (NL-RECS-6).
The system, its release, the processor architecture and the count of logical processors: what a reader comparing the cost of two runs needs, and nothing that identifies the host. None where the platform states no system, the explicit unknown a record keeps.
Returns:
| Type | Description |
|---|---|
str or None
|
For example |
pyflightstream.workspace.naming.point_file_stem
¶
point_file_stem(sim: str, name: PointName) -> str
Return the stem of every file of one point: P<sim>-<point name>.
Parameters:
| Name | Type | Description | Default |
|---|---|---|---|
sim
|
str
|
The simulation id. |
required |
name
|
PointName
|
The point's name. |
required |
Returns:
| Type | Description |
|---|---|
str
|
|
pyflightstream.workspace.naming.resolve_manifest
¶
resolve_manifest(
root: str | Path, runs: str | None = None
) -> Path
Return the manifest file a command reads in the workspace root.
This rule (AD-09) lives in the workspace layer, because it
names a file of the workspace root; :mod:pyflightstream.run.records
re-exports it under its public name and
:mod:pyflightstream.workspace.storage calls it without reaching into
the run layer above it.
Parameters:
| Name | Type | Description | Default |
|---|---|---|---|
root
|
str or Path
|
The workspace root, the folder that holds |
required |
runs
|
str
|
The manifest's file name. None means |
None
|
Returns:
| Type | Description |
|---|---|
Path
|
|
Raises:
| Type | Description |
|---|---|
RunsManifestError
|
When |
pyflightstream.workspace.naming.sim_dir_name
¶
sim_dir_name(sim_id: str) -> str
Render the managed simulation folder.
Parameters:
| Name | Type | Description | Default |
|---|---|---|---|
sim_id
|
str
|
Letters, digits, underscore or hyphen, starting with a letter or digit. |
required |
Returns:
| Type | Description |
|---|---|
str
|
The portable |
Raises:
| Type | Description |
|---|---|
NamingTemplateError
|
If sim_id is empty or contains characters outside the portable alphabet. |
pyflightstream.workspace.naming.sim_id_of_folder
¶
sim_id_of_folder(folder: str) -> str | None
Read a structural simulation folder, returning None for other names.
Parameters:
| Name | Type | Description | Default |
|---|---|---|---|
folder
|
str
|
One folder name, without parent paths. |
required |
Returns:
| Type | Description |
|---|---|
str or None
|
The simulation identifier if the renderer reproduces this folder. |
pyflightstream.workspace.naming.submitted_by
¶
submitted_by() -> str | None
Return the operator running this process, or None if the host names nobody.
identify the user
who ran, transparently for Linux and Windows. One call, not a pair of
sys.platform branches, which would be two paths that drift.
IT LIVES HERE AND NOT BESIDE THE PRODUCTS because run captures it and
post writes it, and post imports workspace rather than the reverse.
Putting it beside the products would have inverted the dependency
direction, which is a design error rather than a lint finding.
IT RETURNS None AND NOT NA. The product layer spells the absence, because
the token belongs to the CSV and provenance surface and this function is
below it. A host that cannot say who is running is a real path rather than
a defensive one: a batch submission with a scrubbed environment and no
password entry reaches it, and inventing a name there would put a false
claim into the one artifact whose purpose is to be believed.
Returns:
| Type | Description |
|---|---|
str or None
|
The operator's name, or None when the host names nobody. |
pyflightstream.workspace.naming.sweep_file_stem
¶
sweep_file_stem(
sim: str, sweep: str, *, prefix: str = POINT_FILE_PREFIX
) -> str
Return the stem of a file about a whole sweep: P<sim>-<sweep> or SUPER-<sim>-....
Parameters:
| Name | Type | Description | Default |
|---|---|---|---|
sim
|
str
|
The simulation id. |
required |
sweep
|
str
|
The sweep's name. |
required |
prefix
|
str
|
|
POINT_FILE_PREFIX
|
Returns:
| Type | Description |
|---|---|
str
|
|