Skip to content

Geometry units and steady starts

A steady attitude sweep starts every point cold, including the first point. The script clears the solution before each solve. To retain the previous warm behavior, set COLD_START: false in the matrix row. The Python builder uses build_steady_sweep(..., cold=False) for the same opt-in.

Warm results can depend on the order of the points. The run continues to record that order. Geometry and setup are emitted once in either mode. This change applies to steady sweeps; it does not clear an unsteady time march or its continuation. Unsteady rows continue to refuse COLD_START.

Physical coordinates in reference moment_point_m, rotor_position_m, rotor x_m/y_m/z_m, reference [[frames]].origin, and probe specifications are metres. Probe coordinates scaled by rotor radius first become physical metres. The builder converts them once through the common length-unit table before emitting a command that takes simulation units. Directions and angles are not lengths and are not multiplied by this factor.

For example, a moment point at 0.25 m is emitted as 250 in a simulation whose length unit is millimetres. A probe 0.1 m from that point is 100 millimetres locally and 350 millimetres in the reference frame. Commands that explicitly take METER, such as frame-origin translation, retain that explicit unit; the placement ledger converts their result back to native coordinates.

The legacy matrix variable ROTOR_ORIGIN explicitly uses simulation units and retains that contract. It is distinct from metre-valued rotor reference fields. Imported raw meshes retain their existing import-unit conversion. No field of custom inflow velocities or coordinates is automatically rotated.

Saved FSM units are decoded only for measured paired global-block headers: (1.0, 5) is metres and (0.001, 2) is millimetres. The latter reuses the 26.124 measurement in, rather than claiming a new licensed test. These are the selected command/display units, not a declaration that every saved coordinate array uses that unit. Paired static controls on build 8172026 imported the same meter-valued square, used frame origins differing by a factor of 1,000, and saved identical meter-valued mesh/frame coordinates after a positive 90-degree X rotation (maximum discrepancy below 1e-10). _fsm.saved_mesh_coordinate_unit therefore separates the measured stored coordinate unit from the display unit. Coverage checks do not apply the millimeter factor to an already meter-valued saved mesh. This millimeter storage interpretation is restricted to the measured build.

Unknown or inconsistent pairs are refused when a physical conversion is needed. An explicit supported simulation-unit setting after opening the file remains available when the user knows its unit.

Offline tests verify conversion and emitted ordering. Equivalent native loads, moments and field behavior still require the release's licensed comparisons; script serialization alone does not establish that equivalence.

Measured OBJ boundary names

Native controls on 26.124, build 8172026, confirmed an o group followed by a g group, repeated g groups, faces before the first g, and a g statement naming several groups. Repeated groups remain separate boundaries, even when their names match. Such duplicate names are selectable by position; a name that matches several boundaries does not choose one arbitrarily.

Faces before the first g form Boundary-1. For g Main Wing, the measured importer retains Main; the reader warns about this choice. It does not treat the whole statement as a multiword name. Reverse g-to-o transitions, reopened o names, empty group statements and multiword o names retain the explicit-sidecar route until their native behavior is measured.

Prescribed-frame evidence

Script.frame_motions records final emitted frame placement, explicit motion attachments, centers, axes, RPM and time-step inputs. Read it after setup has finished because a probe can be emitted before its frame is attached to a motion. Unknown placement or timing carries a reason. Raw commands and ambiguous attachments do not silently become fixed frames.

A saved record can be passed to pyflightstream.script.motion.resolve_frame_motion(record, solver_identity=...). The resolver returns a copy and requires a measured proof matching the actual executable SHA-256, build, version and length unit. A nominal version alone does not activate a transform. The bundled METER proof for 26.124 build 8172026 follows the emitted RPM sign and maps STEP to elapsed time as STEP * dt. It is bound to the measured executable digest. The control used six steps, a 0.00625-second increment and -800 RPM; it established coordinate and timing conventions, not aerodynamic accuracy. Delayed starts and other length units remain unproved. Velocity component bases require their own export-specific proof.

Simulation geometry controls

A setup preset can declare these optional solver settings:

[solver]
simulation_length_unit = "MILLIMETER"
vertex_merge_tolerance_m = 0.0002
geometric_edge_bluntness_angle_deg = 90.0

The workflow applies the simulation unit after the complete saved-simulation OPEN or raw-mesh/CAD import, before dimensional frames and edge detection. METER and MILLIMETER are the measured workflow choices. The source mesh import unit or CAD metadata still declares its physical size. Changing this setting does not authorize reinterpreting those input coordinates.

The merge tolerance is a physical distance in metres. The example emits SET_VERTEX_MERGE_TOLERANCE 0.2 in a millimetre simulation and 0.0002 in a metre simulation. Its typed bounds require a finite nonnegative distance. The current workflow emits the setter after geometry, following the command phase contract. This demonstrates configuration and conversion; it does not establish that the setter repairs an already imported mesh or that its effect is identical before and after import. Mesh-repair acceptance remains a separate native measurement.

The geometric-edge threshold accepts 45 through 179 degrees and is emitted before trailing-edge detection. Its command is documented from 26.122 onward; the workflow does not silently substitute the older trailing-edge command. Detection quality and resulting topology must be checked for the particular mesh.

Unstated settings preserve existing behavior: raw mesh/CAD imports default to METER, and a saved simulation retains its unit. Metre-valued reference origins, rotor positions and other dimensional inputs are converted once to the selected simulation unit. The geometry preparation route converts CAD before a matrix row opens its prepared saved simulation. RPT-082 records the measured unit domain and negative controls.

Reference compatibility

Python-authored ReferenceData keeps normalization_units="NATIVE" by default: its area and length retain their existing native-unit contract. Set normalization_units="SI" to provide square metres and metres explicitly. Workspace REF files already name area_m2 and chord_m; their loader now records SI and the workflow converts once at emission, using the effective simulation unit at that moment. Raw unit settings therefore do not cause a second conversion of stored values. Runtime velocity and reference_velocity_m_per_s remain physical m/s in the case and are emitted in native length units per second. Mach stays dimensionless.