Skip to content

Acoustic signals

The acoustic signals product

A point whose record lists acoustic signals gets, under acoustics/ of its products, the tables below, read from the file the solver's EXPORT_ACOUSTIC_SIGNALS wrote. The export holds, per observer, a block: a line Observer: <name>, a line Position: x,y,z (Fortran-style numbers such as .00,10.0,.00), a line Columns: Observer time (sec), PL (Pa), PT (Pa), PO (Pa) and one row per sample (measured on build 26.124, probe A1). The manual pages of the toolbox (FSM-26.120 pp.374 and 380) do not define the three pressure columns; the probe shows PO = PL + PT in every row, and the package reads PO as the overall pressure and calls PL the loading part and PT the thickness part, which is the customary split and not a vendor statement. The unit of the position is not in the file and is read as metres.

<n> is the observer's place in the export, from 01, and <observer> its name made safe for a file name.

  • Pressure against time, <point>_<n>_<observer>_pressure.csv: TIME_S, PRESSURE_PA, the PO column.
  • Spectrum, <point>_<n>_<observer>_spectrum.csv, with the columns FREQUENCY_HZ, AMPLITUDE_PA and LEVEL_DB: the one-sided amplitude spectrum of PO over the observer time, the real FFT of the samples as they are (no window, mean kept). For N samples at the constant step dt, the sampling rate is 1/dt and the bin width 1/(N dt); bin 0 is |X0|/N (the mean), a bin below Nyquist is 2|Xk|/N, the Nyquist bin of an even N is |Xk|/N, so a cosine of amplitude A on a bin reads A. LEVEL_DB is 20 log10((A/sqrt(2)) / 20e-6 Pa), NA for bin 0 and for a zero amplitude. A step that is not constant (relative spread above 1e-3) gives no spectrum.
  • OASPL, OASPL_DB of <point>_acoustics_summary.csv: 20 log10(p_rms / 20e-6 Pa), p_rms the root mean square of PO about its mean over the whole record; NA for a silent record. The summary has one row per observer, with the columns OBSERVER, X_M, Y_M, Z_M (the position), SAMPLES, TIME_START_S, TIME_END_S, SAMPLE_RATE_HZ, BIN_HZ (the bin width of the spectrum) and OASPL_DB; the sampling rate and the bin width are NA where the step is not constant.
  • Blade-passage harmonics, <point>_acoustics_bpf.csv, with the columns ROTOR, OBSERVER, HARMONIC, FREQUENCY_HZ, BIN_HZ, AMPLITUDE_PA, LEVEL_DB and BIN_OFFSET_BINS, one row per observer, rotor and harmonic: for each rotor of the record with its blade count B and speed rpm, harmonic n (1 to 4) is at n B |rpm| / 60 hertz (the sign of the speed only states the sense of rotation), read at the nearest bin of the observer's spectrum, with the bin frequency, the amplitude and the level. NA when the record states no blades or speed, above the Nyquist frequency, or below one bin width; each NA has a line in post.log. BIN_OFFSET_BINS is the bin read minus the harmonic's frequency, divided by the bin width: zero when the harmonic falls on a bin, NA where either frequency is NA. The amplitude is the nearest bin's and is not corrected, and every nonzero offset has a line in post.log saying that an unwindowed tone off the bin can be underestimated by about 3.9 dB.
  • Directivity, <point>_acoustics_directivity.csv, written only when at least four observers are coplanar and lie on one circle (each within 1e-3 of the radius): per observer the angle about the circle's centre, measured from the first observer and increasing toward the second, in [0, 360) degrees, the radius and the OASPL, as the columns OBSERVER, ANGLE_DEG, RADIUS_M and OASPL_DB. Fewer than four observers, or any off the circle, is not an arc and writes no file.

The manifest and the skips. products.json registers each of these files with kind acoustics, source acoustic_signals and observers, the number of observers of the export. The export is the file the record lists under acoustic_signals; a record that lists none asks for no acoustics, and nothing is said. An export the post cannot read is named under acoustics in the post's skips and warned in post.log, and the other products are written.

The section is not a table. The VTK files of an ACOUSTIC_SECTION, in <point>_acoustic_section/, are the solver's own and are recorded and hashed as outputs of the point (acoustic signals); the post reads none of them, and no table is derived from them.