Acoustic signals
The acoustic signals product¶
A point whose record lists acoustic signals gets, under
acoustics/ of its products, the tables below, read from the file the solver's
EXPORT_ACOUSTIC_SIGNALS wrote. The export holds, per observer, a block: a line
Observer: <name>, a line Position: x,y,z (Fortran-style numbers such as
.00,10.0,.00), a line Columns: Observer time (sec), PL (Pa), PT (Pa), PO (Pa)
and one row per sample (measured on build 26.124, probe A1). The manual pages of
the toolbox (FSM-26.120 pp.374 and 380) do not define the three pressure columns;
the probe shows PO = PL + PT in every row, and the package reads PO as the
overall pressure and calls PL the loading part and PT the thickness part, which is
the customary split and not a vendor statement. The unit of the position is not in
the file and is read as metres.
<n> is the observer's place in the export, from 01, and <observer> its name
made safe for a file name.
- Pressure against time,
<point>_<n>_<observer>_pressure.csv:TIME_S,PRESSURE_PA, thePOcolumn. - Spectrum,
<point>_<n>_<observer>_spectrum.csv, with the columnsFREQUENCY_HZ,AMPLITUDE_PAandLEVEL_DB: the one-sided amplitude spectrum ofPOover the observer time, the real FFT of the samples as they are (no window, mean kept). ForNsamples at the constant stepdt, the sampling rate is1/dtand the bin width1/(N dt); bin 0 is|X0|/N(the mean), a bin below Nyquist is2|Xk|/N, the Nyquist bin of an evenNis|Xk|/N, so a cosine of amplitudeAon a bin readsA.LEVEL_DBis20 log10((A/sqrt(2)) / 20e-6 Pa),NAfor bin 0 and for a zero amplitude. A step that is not constant (relative spread above 1e-3) gives no spectrum. - OASPL,
OASPL_DBof<point>_acoustics_summary.csv:20 log10(p_rms / 20e-6 Pa),p_rmsthe root mean square ofPOabout its mean over the whole record;NAfor a silent record. The summary has one row per observer, with the columnsOBSERVER,X_M,Y_M,Z_M(the position),SAMPLES,TIME_START_S,TIME_END_S,SAMPLE_RATE_HZ,BIN_HZ(the bin width of the spectrum) andOASPL_DB; the sampling rate and the bin width areNAwhere the step is not constant. - Blade-passage harmonics,
<point>_acoustics_bpf.csv, with the columnsROTOR,OBSERVER,HARMONIC,FREQUENCY_HZ,BIN_HZ,AMPLITUDE_PA,LEVEL_DBandBIN_OFFSET_BINS, one row per observer, rotor and harmonic: for each rotor of the record with its blade countBand speedrpm, harmonicn(1 to 4) is atn B |rpm| / 60hertz (the sign of the speed only states the sense of rotation), read at the nearest bin of the observer's spectrum, with the bin frequency, the amplitude and the level.NAwhen the record states no blades or speed, above the Nyquist frequency, or below one bin width; eachNAhas a line inpost.log.BIN_OFFSET_BINSis the bin read minus the harmonic's frequency, divided by the bin width: zero when the harmonic falls on a bin,NAwhere either frequency isNA. The amplitude is the nearest bin's and is not corrected, and every nonzero offset has a line inpost.logsaying that an unwindowed tone off the bin can be underestimated by about 3.9 dB. - Directivity,
<point>_acoustics_directivity.csv, written only when at least four observers are coplanar and lie on one circle (each within 1e-3 of the radius): per observer the angle about the circle's centre, measured from the first observer and increasing toward the second, in[0, 360)degrees, the radius and the OASPL, as the columnsOBSERVER,ANGLE_DEG,RADIUS_MandOASPL_DB. Fewer than four observers, or any off the circle, is not an arc and writes no file.
The manifest and the skips. products.json registers each of these files
with kind acoustics, source acoustic_signals and observers, the number
of observers of the export. The export is the file the record lists under
acoustic_signals; a record that lists none asks for no acoustics, and nothing
is said. An export the post cannot read is named under acoustics in the
post's skips and warned in post.log, and the other products are written.
The section is not a table. The VTK files of an ACOUSTIC_SECTION, in
<point>_acoustic_section/, are the solver's own and are recorded and hashed
as outputs of the point (acoustic signals);
the post reads none of them, and no table is derived from them.