Skip to content

Harmonics

Harmonics: per-station 0P, 1P and 2P

reductions/<point>_harmonics.csv, one per rotor point that has samples at several blade azimuths: an unsteady-rotor point with per-step sectional exports (the last complete revolution) and a quasi-steady wheel (every blade at every clocking).

Columns Content
the run block the run block
ROTOR_ID, ROTOR the declared id and the alias of the rotor
QUANTITY the sectional load: Fx, Fz or Moment
STATION_R_M, R_OVER_R the station's radius in m and as a fraction of the rotor radius
SAMPLES, DISTINCT_AZIMUTHS the blade samples fitted and the distinct azimuths among them
H0 the mean of the quantity at the station, in the quantity's unit
H1_AMP, H1_PHASE_DEG, H2_AMP, H2_PHASE_DEG the 1P and 2P amplitudes (the quantity's unit) and phases (degrees) of the least-squares fit
RESIDUAL_RMS the root mean square of the fit's residual, in the quantity's unit

A harmonic short of distinct azimuths (1P needs 3, 2P needs 5) is NA and said once in post.log. The definition of record is the per-station harmonics.