Skip to content

pyflightstream.cases.freestream (stable)

Generated from the docstrings at build time: every one of the 7 names in the __all__ of pyflightstream.cases.freestream has an entry below. The names a guide or an example uses come first; the others follow under Advanced.

Prepare explicitly declared custom fields for the solver's measured file units.

Advanced

pyflightstream.cases.freestream.MEASURED_FIELD_UNITS module-attribute

MEASURED_FIELD_UNITS = ('METER', 'MILLIMETER')

pyflightstream.cases.freestream.PreparedField dataclass

PreparedField(
    path: str,
    payload: bytes | None,
    provenance: dict[str, object],
)

Effective solver input and the separate source/effective byte identities.

pyflightstream.cases.freestream.field_rows_in_metres

field_rows_in_metres(
    path: Path,
    *,
    form: str,
    source_units: str | None,
    native_unit: str | None,
    data: bytes | None = None,
) -> tuple[str | None, list[list[float]]]

Return a custom field's rows in metres and metres per second (qsteady_rotor).

SI and an undeclared file are read as the manual states the form, in metres and metres per second; NATIVE is converted from the simulation's measured unit. An undeclared file on a simulation whose unit is not the metre is refused, because nothing then says which of the two it is written in, and the rotational velocity the quasi-steady rotor removes from it, composing the relative free stream the fixed blades see, is in metres per second.

Parameters:

Name Type Description Default
path Path

The custom field file.

required
form str

The field's form, STRUCTURED (a header line, then the rows) or UNSTRUCTURED.

required
source_units str or None

The row's FREESTREAM_UNITS: SI, NATIVE, or None where the row does not declare it.

required
native_unit str or None

The simulation's measured length unit, METER or MILLIMETER.

required
data bytes

The file's bytes where the caller already holds them; see :func:read_field_rows.

None

Returns:

Type Description
tuple of (str or None, list of list of float)

The header line (None for an unstructured field) and the rows, positions in metres and velocities in metres per second.

Raises:

Type Description
CampaignConfigError

If a NATIVE field's simulation unit is neither the metre nor the millimetre, an undeclared field sits on a simulation not in metres, or :func:read_field_rows refuses the file.

pyflightstream.cases.freestream.prepare_field

prepare_field(
    path: Path,
    *,
    form: str,
    source_units: str | None,
    native_unit: str | None,
) -> PreparedField

Convert an explicit SI declaration only; undeclared inputs retain their bytes.

The six file columns carry global XYZ and velocity components. In the measured METER/MILLIMETER custom-file boundary, all six use native length units (seconds are unchanged). Multiplication changes representation only. It never rotates vectors or coordinates, and never writes the source.

Parameters:

Name Type Description Default
path Path

The custom field file.

required
form str

The field's form, STRUCTURED (a header line, then the rows) or UNSTRUCTURED.

required
source_units str or None

The row's FREESTREAM_UNITS: SI, NATIVE, or None where the row does not declare it.

required
native_unit str or None

The simulation's measured length unit, METER or MILLIMETER.

required

Returns:

Type Description
PreparedField

The file the solver reads (the source itself where nothing is converted, otherwise a converted copy and its bytes) and the provenance of both.

Raises:

Type Description
CampaignConfigError

If source_units is not SI, NATIVE or omitted, or an SI field cannot be converted: the simulation unit is not measured, or the file has no header, a bad row count or grid count, a non-numeric value or a row of other than six finite columns.

Examples:

>>> import tempfile
>>> from pathlib import Path
>>> path = Path(tempfile.mkdtemp()) / "field.dat"
>>> with path.open("w", encoding="utf-8") as stream:
...     print("0 0 0 10 0 0", file=stream)
...     print("1 0 0 10 0 0", file=stream)
>>> kept = prepare_field(path, form="UNSTRUCTURED", source_units=None,
...                      native_unit="MILLIMETER")
>>> kept.path == str(path), kept.payload
(True, None)
>>> converted = prepare_field(path, form="UNSTRUCTURED", source_units="SI",
...                           native_unit="MILLIMETER")
>>> converted.payload.decode().splitlines()
['0 0 0 10000 0 0', '1000 0 0 10000 0 0']

pyflightstream.cases.freestream.prepare_rotating_field

prepare_rotating_field(
    path: Path,
    *,
    form: str,
    source_units: str | None,
    native_unit: str | None,
    hub_m: tuple[float, float, float],
    axis: tuple[float, float, float],
    omega_rad_s: float,
) -> PreparedField

Write the field a blade held still meets: the user's inflow less the rotational velocity.

The user's file is the TOTAL velocity of the air at the disc, in the global frame, and this composes the RELATIVE free stream the fixed blades see: the rotational velocity of each point is removed, never added. A blade turning at omega (right-hand about the unit axis, signed by the rotor's hand) moves at omega axis x (p - hub), so the air relative to it, which is what a blade held still must meet, is::

v_rel(p) = v(p) - omega axis x (p - hub)

Computed in metres and metres per second and written in the simulation's unit, as :func:prepare_field writes an SI field. The source is never written; the effective file is a new one named by its own digest, and its provenance says what was added. The rotation is the free stream's meaning applied to the file (the air seen from the turning blade); no licensed run has compared this field with SET_FREESTREAM ROTATION yet.

Parameters:

Name Type Description Default
path Path

The custom field file.

required
form str

The field's form, STRUCTURED (a header line, then the rows) or UNSTRUCTURED.

required
source_units str or None

The row's FREESTREAM_UNITS: SI, NATIVE, or None where the row does not declare it.

required
native_unit str or None

The simulation's measured length unit, METER or MILLIMETER.

required
hub_m tuple of float

A point of the shaft, (x, y, z) in metres, in the field's frame.

required
axis tuple of float

The shaft's direction, a unit vector in the field's frame.

required
omega_rad_s float

The rotor's angular speed in radians per second, right-hand about axis and signed by the rotor's hand.

required

Returns:

Type Description
PreparedField

The new field file named by its own digest, its bytes in the simulation's unit, and its provenance.

Raises:

Type Description
CampaignConfigError

If omega_rad_s, hub_m or axis is not finite, axis is not a unit vector, the simulation's unit names no scale, or the file is refused as :func:field_rows_in_metres refuses it.

pyflightstream.cases.freestream.read_field_rows

read_field_rows(
    path: Path, *, form: str, data: bytes | None = None
) -> tuple[str | None, list[list[float]]]

Return a custom field's header line (STRUCTURED) and its rows of six numbers.

The form was checked by the builder's reader before this is asked; this reads the numbers and refuses only what would make them unusable.

Parameters:

Name Type Description Default
path Path

The custom field file.

required
form str

The field's form, STRUCTURED (a header line, then the rows) or UNSTRUCTURED.

required
data bytes

The file's bytes where the caller already holds them, so one read serves both the rows and a hash of them; read from path where omitted.

None

Returns:

Type Description
tuple of (str or None, list of list of float)

The header line (None for an unstructured field) and the rows, six numbers each, as written.

Raises:

Type Description
CampaignConfigError

If the form is unknown, the file is not UTF-8 text, a structured field has no header, the file holds no row, a value is not numeric, or a row is not six finite columns.

pyflightstream.cases.freestream.require_measured_unit

require_measured_unit(native_unit: str | None) -> str

Return the simulation's unit when a custom field is measured in it, else refuse.

The one home of the whitelist (PFS-2119.002): :func:prepare_field, :func:field_rows_in_metres and :func:prepare_rotating_field all write or read a field in the simulation's unit, and the solver's reading of a custom file is measured for the metre and the millimetre only.

Parameters:

Name Type Description Default
native_unit str or None

The simulation's length unit, or None where the caller states none.

required

Returns:

Type Description
str

The unit, METER or MILLIMETER.

Raises:

Type Description
CampaignConfigError

If the unit is neither METER nor MILLIMETER, citing RPT-083.

Examples:

>>> require_measured_unit("MILLIMETER")
'MILLIMETER'