Skip to content

Run again, resume, records

This page shows how to run a matrix a second time, how to redo a point, and how to read and correct the records that every run leaves.

runs.json, in the workspace root, holds one record per point: its inputs, its status, its times and the verdict on its convergence. The commands on this page read it or change it. You never edit it by hand.

Writers hold runs.json.lock, which names their process. A live writer or a lock with no readable process identity refuses another writer. If the named process is gone, the next writer takes over under an exclusive operating-system lease and warns. You do not need to remove a departed writer's lock by hand.

The run manifest now uses schema version 2. Reading a valid version 1 manifest from 0.5.x validates it, copies its exact bytes to archive/<stamp>/runs.json, then atomically upgrades it under the writer lock. History and recorded evidence are preserved. An invalid or future manifest is refused without rewriting it. The first read therefore needs write access to the workspace. Restoring an old archive also reads version 1 and writes version 2.

The status of a record

Status Meaning
PLANNED run registered the point and has not started it yet.
RUNNING The solver is running the point on this machine, or the run was interrupted before the point ended.
SUBMITTED The point was sent to a cluster and its result has not been collected.
COMPLETED The point ended. Its verdict says how: converged, iteration_limit or failed.

A point that ended without a usable result is recorded COMPLETED with the verdict failed, and the record keeps the reason. The commands show such a point by the word of its reason, FAILED_EXECUTION or another FAILED_ word, so that it is not read as a success. Results and tables explains the verdicts.

Restart from a saved solution

Use a row's RESTART entry to start new points from a recorded solution. To continue each selected point from its own last solution instead:

cfd-matrix run polar --local --restart
cfd-matrix run polar --local --restart --sims 1001

Every selected source must have saved solution state. A source from another point must be completed. run --local --restart can also continue a point left RUNNING by an interrupted local run, after you confirm its process has stopped. Sources and local executables are checked before archiving. Add --one-run-at-a-time to reserve the machine against other guarded local runs before archiving. The previous folders and records are archived, then the solution files are copied into new point folders. Existing evidence is preserved. This option cannot be combined with --resume or the force-rerun options. --resume selects points to run and does not request saved solution state.

Starting a sliding-mesh row from its own frozen-rotor solution

RESTART = MRF is not a source point. It runs a steady stage on the row's own two-zone mesh in the same point folder and job, and starts the time-accurate stage from its solution; the folder holds precursor.cfg, pre_zone_<i>.cfg, run_mrf.sh, precursor.log, precursor.csv and the staged solution_<zone>_<level>.dat files beside su2.cfg. The record of the point states precursor (true) and, in its provenance, the iterations and the stop level. A row with - records nothing new. The point is judged on the time-accurate stage as before (su2.csv); the steady stage's history is evidence only. A failed steady stage ends the job with status 91 to 94 and a PRECURSOR_FAILED line in the point's stderr.log; the point is then recorded failed. --force-rerun-all writes the stage files again with the new batch. See SU2 workspaces.

A source that runs earlier in the same job

With --batch N, a source that is not completed yet is accepted when it is in the same job as the point it feeds: the job runs the rows in sequence, so the solution exists when the dependent starts. cfd-matrix plan --batch N lists each such pair. The job script reads the source's job.exit and, only when it is 0, copies the solution into the dependent's folder with cp. The job script needs only a POSIX shell: the source files and the names the solver reads are written into it at submission, and no Python is called on the compute node. The staging needs the solver's restart file to exist and not be empty, not collected products. When sha256sum exists on the node, the script writes the digests of the staged files to restart-staged.sha256 in the dependent's folder; nothing reads that file. su2.cfg is never edited: it was written at submission from the source's rendered configuration. If the source did not end with status 0 (or its job.exit is missing, for a killed job), the dependent is not run: its job.exit is 97 and its stderr.log holds one line saying why. If the staging fails, job.exit is 98 and stderr.log holds one line naming the restart file that is missing or empty. The job goes on with the next run. collect marks such a run failed with that reason; a run the script ended with a failure and left no solver output is never left outstanding. A source later in the job is moved ahead of its dependents (runs of a job share no state, so no result changes). Points that feed each other are refused. This holds for SU2 with a steady source whose rendering fixes the restart file: OUTPUT_FILES, when stated, holds RESTART, WRT_BINARY_RESTART is not NO, and RESTART_FILENAME is a plain name ending in .dat (default restart_flow.dat); otherwise the run is refused naming the key. A source that is neither completed nor in the same job (no --batch, another job, or left out by --points or --sims) is refused as before. With --force-rerun-all both rows run again in the job, fed from each other's new attempt.

A two-zone (sliding-mesh) point cannot take part in a RESTART, as the source or as the dependent: it is refused at planning and submission; run the sliding point cold.

SU2 copies its configured RESTART_FILENAME (default restart_flow.dat or restart_flow.csv) to restart-input.dat or .csv and sets RESTART_SOL and SOLUTION_FILENAME. READ_BINARY_RESTART matches the saved binary or ASCII output format. OpenFOAM copies every field of the latest positive time directory, requires U and p, sets startFrom latestTime and adds the requested iterations to the saved time. PyFR copies its most recently written .pyfrs output to restart.pyfrs together with its saved native mesh.pyfrm, and runs pyfr restart without reimporting the mesh. A different source mesh is refused. Its writer saves a solution every tend time units; a restarted run adds that duration to the saved time. PyFR keeps its existing force window relative to the new start time.

The point fields restart_from, restart_directory and restart_sha256 in runs.json name the source point, its saved folder and the SHA-256 of each copied solution input. A source whose solution is absent or changes before staging is refused with the source point named. Other adapters warn and skip a restart; --warning-refusals makes the skip a refusal.

For grouped forces, the adapter returns NeutralResult.force_groups; collect places it at points[].result.force_groups in the campaign summary. Each requested group and TOTAL carries coefficient values with explicit axes and kinds, using the result's reference values. The per-group values are read from the retained solver history files; no group CSV is written.

Running a matrix again

A point that has a record refuses a second run:

cfd-matrix run polar
matrix not run: point '1001/DP-M200AL+000' already recorded COMPLETED; use --resume to run only the points not yet recorded, or --force-rerun POINT to redo one

Nothing ran and nothing changed. Choose one of the three options below.

Run only what is new: --resume

cfd-matrix run polar --resume
  1001/DP-M200AL+000  skipped: COMPLETED
  1001/DP-M200AL+020  skipped: COMPLETED
  1001/DP-M200AL+040  skipped: COMPLETED

--resume skips every point recorded COMPLETED or SUBMITTED, whatever its verdict, and runs the rest. Use it after adding rows or sweep values to a matrix, and after a run that was interrupted. Plan the grown matrix first: the points already recorded stay valid, because a point is stale when a file it read (its setup, reference, pproc or geometry file) changed, never because the matrix gained a row. collect and post read the old points as before. A skipped point whose verdict is failed says how to run it again:

  1001/DP-M200AL+040  skipped: COMPLETED failed; redo it with --force-rerun 1001/DP-M200AL+040

Fixing the cause of a failure and typing --resume therefore does not run the failed point; name it with --force-rerun, or every failed point with --force-rerun-all.

A RUNNING point is skipped because its local process or cluster job may still exist. After confirming it has stopped, name it with --force-rerun to redo it.

Redo one point: --force-rerun

cfd-matrix run polar --force-rerun 1001/DP-M200AL+020
archived previous evidence: /home/you/campaign/archive/20261113T135750Z
  1001/DP-M200AL+000  skipped: COMPLETED, not named by --force-rerun
  1001/DP-M200AL+040  skipped: COMPLETED, not named by --force-rerun
[1/1] 1001/DP-M200AL+020  running
[1/1] 1001/DP-M200AL+020  COMPLETED converged in 0 s

The point is archived before it runs again, and nothing is deleted:

  • runs.json is copied to archive/<stamp>/runs.json;
  • the point folder moves to archive/<stamp>/sims/sim_<POL>/datapoints/<point>/;
  • the earlier record joins the history of the point.

<stamp> is the date and time of the move, in UTC. Repeat the option to redo several points. The short name DP-M200AL+020 is enough when only one sim of the matrix has a point of that name.

Redo every point: --force-rerun-all

cfd-matrix run polar --force-rerun-all

Every selected point is run again whatever its recorded state: not yet run, SUBMITTED, RUNNING, COMPLETED, failed, with or without a job on record. A recorded point is archived first as --force-rerun archives it, so its stdout.log, history.csv, restart folder and job.exit stay together in archive/<stamp>/ and the new attempt starts in an empty folder. A point that was SUBMITTED or RUNNING prints one warning line: a job of the earlier submission may still be running, and cancelling it is your action, because the library does not talk to the scheduler. The option works with --points, --sims and --batch (plan the batch again first: it gets a new folder, and the folder of the earlier batch stays where it is). Only two things still refuse. The validity of the inputs and of the row refuses a point, for example a missing mesh or an input changed after planning. A point folder or output that exists with no record is data the registry does not know, so it refuses with existing output; refusing overwrite; move or delete it yourself and run again. The option cannot be combined with --resume, and cannot be combined with --force-rerun.

Continue a time-accurate point: --continue

cfd-matrix plan polar
cfd-matrix run polar --continue --sims 2001

After you raise REVOLUTIONS (or TIME_ITERATIONS) in the row of a finished time-accurate point, or when its cluster job ended early and its record is COMPLETED with a failed classification, --continue runs each selected point on from its latest restart files, in its own folder. It is a separate option because a recorded point refuses a second run unless an option says what to do with it: --resume keeps skipping it, and --force-rerun starts it again from step 1.

A job killed by its walltime after SU2 wrote its history is recorded failed by a plain collect. A job that ended before SU2 wrote anything (cancelled in the queue, killed while it staged) leaves its point SUBMITTED with no job.exit, which collect cannot tell from a job still queued, and so does a point of a batch job that never started. Once you know such a job has ended, declare it:

cfd-matrix collect polar --ended 2001/DP-M053AL+000

--ended (a provisional name) takes one or more POL/DP-name ids and seals each point COMPLETED with a failed classification and the error FAILED_EXECUTION: job ended without job.exit (declared with --ended); every file of the point folder stays as it is. It refuses, changing nothing, an id no record carries, a point that is not SUBMITTED, and a point whose folder holds job.exit (a plain collect reads that one). The point then continues with --continue from its latest restart pair, or, without one, runs again with the force-rerun options.

  • runs.json is copied to archive/<stamp>/runs.json;
  • the earlier record joins the history with continued true (cfd-workspace history lists it as continued);
  • the files the new run writes again (its configuration, history, logs and job files) move to continued/<n>/ in the point folder, continued/1/ the first time; the restart files and the mesh stay where they are;
  • the new record carries a continuation mapping: restart_iter, the solver iteration it restarts at, kept, the folder of the earlier evidence, moved, the files moved there, and segments, every segment's first_step, last_step and folder (. for the current one).

collect joins every segment's history in step order. The option cannot be combined with --restart, --resume, the force-rerun options or --batch. It refuses, changing nothing, a point with no record or not COMPLETED, a row that is not time-accurate, a row whose other keys changed (only the run length may grow, and the scheduler's WALLTIME, NCPUS and hpc. overrides), a run length that fell, a point with no restart files, and a point with nothing left to march. See SU2 workspaces for the solver keys.

Reading the records

These commands change nothing. Each takes --json or --csv to print its rows for a program.

cfd-matrix status --points
SIM   POINT       MATRIX  STATUS     WAS  ITER  RESIDUAL  WALL  BUILD   WHERE
1001  M200AL+000  polar   COMPLETED       2     0.01      0.03  mock-1  local
1001  M200AL+020  polar   COMPLETED       2     0.01      0.03  mock-1  local
1001  M200AL+040  polar   COMPLETED       2     0.01      0.03  mock-1  local
3 datapoint(s): COMPLETED
plan/polar: made from the matrix on disk
post/polar: no post yet
Command Prints
cfd-matrix status One row per polar, the points of one simulation of one matrix, as pyfs-matrix status prints it: SIM, POLAR (the name of its points with the swept field written +sweep), SWEEP (what varies), POINTS (recorded out of planned, 3/4; only the recorded count when the matrix has no plan receipt), MATRIX and STATUS: the one word when every point shares it, otherwise the count of each (COMPLETED 2, FAILED_MARKED 1, planned 1). A point the plan receipt post/<matrix>/plan.json names and no record carries reads planned, in lower case because no recorded status is written so. Then the totals, and for each matrix one line on its plan (made from the matrix on disk, or made from another revision of the matrix; plan it again) and one on its post (when it was written, whether it is complete, how many recorded runs it does not hold yet). --points gives one row per point: SIM POINT MATRIX STATUS WAS ITER RESIDUAL WALL BUILD WHERE, with a trailing ERROR column when a shown point has one; WAS is what a marked point was before you marked it. --failed keeps the polars with a failed point. --status WORD keeps the polars with a point in that status or verdict, repeatable, and refuses a word no status takes; FAILED_* matches every word that starts with FAILED_. --sims, --matrix, --json (one document with the rows and the freshness) and --csv select and print the same rows. A sim that holds no record and no planned point is named on standard error; the exit code is 1 only when every sim named holds nothing.
cfd-workspace show 1001/DP-M200AL+020 The card of one point: status and verdict, solver and version, flight condition, iterations and coefficients once collected, folder, times and error if any. show 1001 lists the points of the sim, one line each. --verbose prints the whole record: inputs, fingerprints, every field that has a value.
cfd-workspace history 1001 The current and the earlier records of a sim or a point, with the archive folder of each earlier one.
cfd-workspace log What happened, in time order: the commands and, for each point, registered, started and finished. --problems keeps the failures, --since 2h the last two hours, --open the runs that started and have no end.
cfd-workspace diff RUN_A RUN_B Two records, field by field. The exit code is 1 when they differ. The fingerprints and output paths, which differ whenever two points do, are folded into one line; --verbose lists them.
cfd-workspace trace post/polar/polars/P1001-TOTAL-ACOEF.csv The runs behind a collected file, with the number of input files each was made from; --verbose lists the fingerprints.

An empty answer keeps its heading and totals and says why: no recorded sim yet: run a matrix first, no failed point, or no recorded point matches the selection. The times are printed in the time of this machine, to the second; the records keep the full UTC time, which --json prints.

An earlier record is named by its point and its archive stamp, as history prints it:

cfd-workspace history 1001/DP-M200AL+020
run                                  kind      when                 status     classification  archive
1001/DP-M200AL+020                   current   2026-11-13 10:57:50  COMPLETED  converged
1001/DP-M200AL+020@20261113T135750Z  archived  2026-11-13 10:57:50  COMPLETED  converged       archive/20261113T135750Z

Recording your own verdict

The verdict of a record comes from what the solver wrote. When you have looked at a point and judge it differently, record your verdict. Both commands show what they would do and change nothing until you add --apply.

cfd-workspace mark-failed --sims 1001 --points DP-M200AL+040 --reason "residual stalled"
would mark 1001/DP-M200AL+040 failed (was COMPLETED converged)
preview only; add --apply to change the records
cfd-workspace mark-failed --sims 1001 --points DP-M200AL+040 --reason "residual stalled" --apply
marking 1001/DP-M200AL+040 failed (was COMPLETED converged)
marked 1 point(s) failed; the manifest before is in /home/you/campaign/archive/20261113T140213Z

Without --points, every point of the named sims is marked. A point that is RUNNING is refused with stop the run first: a live run would seal it over the mark. After a mark, status and the error of the point in the collected summary read FAILED_MARKED: <your reason>; collect keeps the reason and the result keeps the class the solver's own evidence gives.

cfd-workspace mark-converged --sims POL --reason TEXT records that completed points converged, for example a point that reached its iteration limit with steady forces. It needs a reason. collect then reads the point as before: its row carries your verdict in classification, and the result keeps the class the solver's own evidence gives. It refuses a point that has not completed and a point that was marked failed:

refused 1001/DP-M200AL+040: marked failed
nothing marked

Your verdicts are kept in marks.json with their reason and their time, and runs.json as it was before the change is copied to archive/<stamp>/.

Collecting over a file you edited: --overwrite

collect and post replace a table only when it is the file the manifest (post/<matrix>/products.json) recorded. A file you edited by hand, or one another tool left under post/<matrix>/, stops the command, and the message names the file:

<workspace>/post/full/polars/P7001-TOTAL-DIM.csv: unrecorded or edited output; refusing overwrite; move it aside, or run the command again with --overwrite to replace it

cfd-matrix collect --overwrite and cfd-matrix post --overwrite replace every such file and go on through every point: nothing stops in the middle. The manifest is then written from the new files, so the recorded digest of a replaced file is that of the new bytes, and the next collect without the flag is clean. A linked file is still refused. --archive keeps a copy of what was replaced under archive/<stamp>/.

Bringing a file back

cfd-workspace restore runs
would restore runs from archive/20261113T140213Z/runs.json
preview only; add --apply to restore

restore takes what to bring back from the latest archive folder that holds it, or from the one you name with --stamp:

Word Restores
runs runs.json
storage storage_management.json
products the collected files of the matrix named with --matrix
plan the plan receipt of the matrix named with --matrix

Records for folders that have none

cfd-workspace rebuild --matrix NAME writes records for sim folders that are on disk and have no record. It reads the plan of the matrix to know which points to expect. It previews unless --apply is given.

Clearing a sim to run it again

cfd-workspace archive 1001
archived sim 1001 (3 point(s)) to archive/20261113T140557Z; sims/sim_1001/ is removed

archive moves the whole folder of a sim to archive/<stamp>/ and its records to the history, so the sim can run again in a clean folder. Unlike the commands above it acts at once, without a preview, as archive does in pyflightstream. To see what it would move, look first with cfd-matrix status --points --sims 1001. It does not look at the status of the runs: do not archive a sim that is still running.

How a point is named

The folder of a point is sims/sim_<POL>/datapoints/DP-<name>/. The name is built from the FLIGHT_CONDITION of the row: each key of the cell, in the order of the cell, becomes a short code followed by its value, multiplied by a scale, rounded and padded with zeros. The same flow condition has the same name in every workspace.

Key Code Scale Width Example
MACH M 1000 3 0.85 gives M850
TASmps V 10 4 34 m/s gives V0340
REmi RE 100 3 5 million gives RE500
ALTFT ALT 1 5 5000 ft gives ALT05000
dISA DT 10 4, signed 10 K gives DT+100
RHOkgm3, MUPas, ASMPS, TK, PPA RHO, MU, A, T, PS 10000, 1e9, 10, 10, 1 5, 5, 4, 4, 6 1.225 kg/m3 gives RHO12250
ALPHA, BETA AL, BE 10 4, signed 2.5 degrees gives AL+025
ADVANCE_RATIO or J J 100 4, signed 1.0 gives J+100
RPM RPM 1 5 800 rev/min gives RPM00800
roll_rate, pitch_rate, yaw_rate P, Q, R 10 4, signed 2.5 gives P+025

DP-M850RE500AL+025 is Mach 0.85, a Reynolds number of 5 million and alpha 2.5 degrees.

  • A signed field counts its sign in the width.
  • A key without a code, such as a key that only one solver reads, is written as its name in upper case followed by its value. A row with no FLIGHT_CONDITION is DP-NOCOND.
  • The order of the keys in the cell is the order in the name, so reordering the cell renames the points.
  • Two sweep values of one row that round to the same name are refused by plan, with both values in the message.

A workspace made with an early version can hold folders named DP- followed by 20 letters and digits. Their records keep working. Planning such a matrix again registers its points under the new names, so finish or archive the old campaign first.

Management path safety

Management destinations must stay inside the workspace without passing through a symbolic link or Windows junction. Sync skips linked source folders; restore refuses linked source trees.

Restore refuses symbolic links and junctions anywhere in an archived product tree before replacing live products.

Marks apply to the execution they judged. A forced rerun keeps the old mark in the journal but does not inherit its verdict.

The grown-matrix digest exception applies to matrix inputs. A tracked geometry file with the .fs extension is still checked for changed bytes.