Adapter contract¶
A solver adapter is a Python package, cfdbender.solvers.<name>, that
translates a planned point into one solver's input, runs the solver, says how
the run ended and reads the results back. Everything else (the matrix, the
flight condition, the point names, the run record, the tables) belongs to the
core and is the same for every solver. The architecture
page shows where an adapter sits.
This page states each clause an adapter must satisfy. A clause is numbered so
that a test, a review or a bug report can name it. cfdbender.testing holds
the assertions that prove the clauses; the last section shows how to call
them.
The words used here: must is a clause every adapter satisfies; may is
an optional behavior an adapter declares by providing it. The point
folder is sims/sim_<POL>/datapoints/DP-<name>/. The s, r and p files
are the row's setup, reference and post files.
The five functions¶
An adapter exposes five functions at its package boundary. The core calls them in this order and never anything else.
def validate_row(row: MatrixRow, workspace: RowInputs) -> RowRequirements: ...
def translate(point: AdapterPoint) -> str: ...
def execute(point: AdapterPoint, *, check_ram: Callable[[], None]) -> ExecutionResult: ...
def classify(result: ExecutionResult) -> Classification: ...
def collect(point: AdapterPoint) -> NeutralResult: ...
| Function | When | It may | It must not |
|---|---|---|---|
validate_row |
planning, once per row | read inputs through workspace; refuse |
write a file; launch a process |
translate |
before a run or a staging | return the solver input as text | write; depend on the clock or the machine |
execute |
a local run, once per point | create the point folder, write, run the solver once | touch anything outside the point folder; overwrite |
classify |
after execute, and inside collect |
judge numerical evidence | call a run converged from its exit code |
collect |
cfd-matrix collect |
read the saved outputs | write; run anything |
The types come from cfdbender.core.matrix (MatrixRow),
cfdbender.core.plan (RowInputs, RowRequirements),
cfdbender.core.adapter (AdapterPoint, SolverAdapter) and
cfdbender.core.results (ExecutionResult, NeutralResult, Coefficient,
References, Iteration, Classification).
Registration and boundaries¶
C-01. An adapter is registered by one entry, name to package, in
cfdbender.solvers. It is loaded by that exact name; an unknown name is
refused with the list of available solvers.
C-02. The package exposes the five functions above with those signatures. An adapter is a module, not a class: the functions are module attributes.
C-03. An adapter imports the core, cfdbender.geometry,
cfdbender.solvers._host and its own package. It never imports another
adapter's package and never imports pyflightstream. An adapter that needs
another solver's run (QPROP needs XFOIL polars) asks the registry for it by
name and calls a function that adapter exports for that purpose.
C-04. An adapter never imports cfdbender.matrix, cfdbender.workspace
or cfdbender.hpc. The applications call the adapter, never the reverse.
C-05. Importing an adapter imports no solver binding and launches nothing. A solver's Python binding is imported only inside the child process that runs it.
Planning: validate_row¶
C-06. validate_row only reads. It writes no file, creates no folder and
launches no process.
C-07. Every input byte is read through the tracked reader
(workspace.read_bytes, workspace.read_toml, and the prepared
workspace.setup, workspace.reference, workspace.post). The reader
records the SHA-256 of each file, and the core checks those digests again
before the point runs and before it is collected. A file opened any other way
is invisible to that check. A path outside the workspace is refused. Planning reads and
hashes each file once, however many rows and points share it; a file larger than 8 MiB is
streamed through its digest, and workspace.track records such a file without returning its
bytes. A file that changes while planning is refused.
C-08. An invalid input is refused with a ValueError whose message names
the key or value at fault and, where a choice exists, the accepted values.
The core adds the data row and the POL.
C-09. A key of the s file that the adapter does not know is refused at
planning, never ignored: the refusal names the file, the key as written and the
closest known key. A key of the r or p file that the adapter does not read is
not refused: it is warned about once, naming the row, the file and the key, and
skipped (RowInputs.warn_unread). One exception is explicit: an adapter may
declare a native passthrough namespace of the s file with the attribute
NATIVE_PASSTHROUGH, and a key inside that namespace is forwarded to the solver
unread. SU2 declares the upper-case native option names (MARKER_FAR, CFL_NUMBER,
and so on); every other unknown key, such as a lower-case one, is refused, and every
other adapter has no namespace, so it refuses an upper-case key too.
C-10. validate_row returns at least one action (a short phrase the plan
listing prints after "would:" under --verbose) and every output file the point will write, as
templates under sims/sim_{pol}/datapoints/{point}/. An adapter that declares
no action or no output is refused by the core, as is an output outside
sims/ or post/. After a run that is not failed every declared output
exists; the core records a point with a missing declared output as failed, and
the record holds a digest of every declared output. A solver may write other files
(QPROP's sections.plan and section folders, OpenFOAM's time directories); they are
not declared, not digested and not part of the record.
C-11. The adapter accepts the full shared matrix header. It reads the parsed row it is given and never reads the matrix file itself.
C-12. An adapter that takes a mesh or a geometry file accepts it from the
MESH column and reads it through the tracked reader. Where the s file
may also name it, the two must agree or the row is refused.
C-13. An adapter does not spell a mesh folder name. It asks the core's
mesh resolver, which reads inputs/mesh/ first and then the earlier folder
names.
C-14. The row's FLIGHT_CONDITION is the authority on the air and the
attitude. The adapter resolves it with cfdbender.core.flight and never with
an atmosphere of its own. A value that the s, r or p file also states must
agree with the row or the row is refused.
C-15. VAR_NAMES_VALUES overrides arrive already applied in
workspace.setup and in point.setup. The adapter does not apply them
again.
C-16. A WORKFLOW the adapter does not implement is refused at planning,
naming the workflow it accepts.
C-17. Every point of a sweep is validated at planning, not only the first value, so that no point fails on input a plan could have refused.
Translation and staging: translate, stage¶
C-18. translate returns ASCII text and returns the same bytes every time
for the same planned point. It writes nothing.
C-19. translate verifies the point first (point.verify()): the
init.toml solver and every planned input digest. A changed input refuses
with the instruction to plan again.
C-20. A local run and a cluster job read identical solver inputs. One staging routine writes them for both.
Execution: execute¶
C-21. execute creates, writes and changes files only inside the point
folder.
C-22. execute refuses when the point folder or any declared output
already exists. A second execution leaves every byte of the first unchanged.
C-23. execute calls check_ram before it writes and repeatedly while
the solver runs, and uses the host memory guard, which refuses below 0.5 GiB
of free memory. When the guard trips during a run the child process tree is
stopped and reaped.
C-24. A local solver run takes the one-run-per-machine lease only when the
user turns the guard on with a flag or an init.toml key. By default concurrent
runs are allowed and only the free-RAM floor refuses.
C-25. The run is bounded: the adapter's timeout_s option, itself bounded
by the row's WALLTIME. On a timeout the whole child process tree is stopped,
the captured channels are kept and the point is failed.
C-26. The solver is launched without a shell and without a console
window. Its standard output and standard error are captured to stdout.log
and stderr.log in the point folder.
C-27. A local run writes execution.json in the point folder with at
least the process exit code. collect must also work without
that file, because a cluster job does not write it.
C-28. An expected failure (a missing executable, a refused input, a solver
that exits with an error) is raised as ValueError or OSError, or returned
as failed evidence. The core records the point as failed and runs the next
one. An adapter does not catch other exceptions to present a programming
error as a solver failure.
C-29. The executable is chosen in this order: the build named by the
row's SOLVER_BUILD (through inputs/executables.toml), the s file's
[solver] table, then the environment variable and the PATH lookup the
adapter documents. Launcher tokens (for example mpirun -np 8, or a
WSL prefix) precede the executable verbatim. A missing executable refuses
before anything is written.
C-30. A mesh is linked into the point folder, never copied: a relative symbolic link, or a hard link where the host cannot make symbolic links. The linked bytes are checked against the planned digest.
Classification: classify¶
C-31. classify returns exactly one of converged, iteration_limit or
failed.
C-32. Process success is not convergence. Exit code zero with no
numerical evidence is failed. A non-zero exit code is never converged.
C-33. converged requires affirmative numerical evidence, and the
adapter states in its documentation what that evidence is:
| Solver | A point is converged when |
|---|---|
| SU2 | the solver prints its convergence message after the last iteration line of its log (a message followed by more iterations does not count) |
| OpenFOAM | the force output and the log end on the same iteration, and on it SIMPLE reports convergence or every required initial residual is below the residual target |
| PyFR | no value is non-finite and the two halves of the averaging window agree within the row's tolerance |
| XFOIL | the polar holds a row at the requested angle of attack |
| QPROP | the operating table holds a parsed row and the output reports no convergence failure |
C-34. iteration_limit means the solver used its whole iteration or time
budget without the evidence of C-33. A solver that has no such budget (XFOIL,
QPROP) never returns it.
C-35. classify depends only on the ExecutionResult it is given.
collect rebuilds that evidence from the saved files and reaches the same
class as the one recorded when the point ran.
Collection and results: collect¶
C-36. collect only reads. It verifies the point, reads the saved
outputs, and neither writes nor launches anything.
C-37. The NeutralResult carries, for every coefficient, a finite value,
its axis (x, y or z) and its kind (force or moment); the reference
area and length (positive, finite), the moment origin (three coordinates), the
name of the axis system and the direction of positive x, y and z; the
iteration history; the classification; and the solver version.
C-38. A coefficient keeps the name, the sign and the normalisation the
solver prints. The adapter does not rotate a frame or renormalise a
coefficient unless it documents it and reports both. Where a solver reports
in two frames, each coefficient states its frame. The tables of collect add
the neutral columns CL, CD and CM beside the solver's own names; which
of its names an adapter gives them is stated in one table, core/neutral.py,
and a solver with no such coefficient writes NA. The neutral CL, CD and CM
are defined once, in one standard frame (lift normal to the freestream, drag along it,
both from the row's ALPHA and BETA; pitching moment nose-up positive about the row's
moment reference point), and the adapter's own reading is transformed into it by
core/neutral.py, the only place that does so; the Results page gives the
frame and, per solver, the native column, the transform and the sign. A rotor-capable adapter
also maps into the rotor frame (CT, CQ, CP, CN, CY, J, EFFICIENCY; x along the
thrust, z up, y completing the right-handed frame). The solver's own columns stay unchanged
beside the neutral ones. QPROP's efficiency, advance ratio and power entries are not
forces or moments but use the coefficient record shape (a value, an axis and a kind)
by convention, so the result has one format.
C-39. The references in the result are the ones the solver used: read from the r file, or read back from the solver's own input, or, for a solver with fixed references, stated by the adapter:
| Solver | Reference area and length | Moment origin |
|---|---|---|
| SU2 | read back from the configuration the solver used | read back from the same configuration |
| OpenFOAM | the r file | the r file |
| PyFR | unit chord; dynamic pressure 0.5 | no moment is reported |
| XFOIL | unit chord and unit span | the quarter chord |
| QPROP | the disk area and the diameter | the hub center |
C-40. The history counts iterations from one and carries a linear, non-negative residual; a solver that prints a logarithm or counts from zero is converted by its reader. A solver that reports no iterations (XFOIL, QPROP) writes one marker, iteration 1 with residual 0, and its documentation says that the marker is not a measurement.
C-41. An output table is read by its column names, never by column position.
C-42. A failed result may carry no coefficient. Any other result
carries at least one.
C-43. An adapter may add solver-specific evidence to the result it returns (SU2 adds the route it ran, PyFR the averaging window). It never removes or renames a common field.
C-44. solver_version is the version the solver printed in its own
output, or the text unknown when the solver prints none. A row's SOLVER_BUILD
must be the version that ran. When the executable can state its version without a
case (--version: SU2 on its executable route, PyFR), preflight checks it and
the run is refused before any point starts; for every other solver, and for an
executable that does not answer, the version a point printed is checked after
the run and a mismatch fails that point.
Cluster jobs: optional¶
An adapter declares these behaviors by providing the attribute.
| Attribute | Meaning |
|---|---|
stage(point) |
Write every file a job reads into a new point folder, without running the solver. |
STAGED_CONFIG |
The file in the point folder that the job's solver actually reads (QPROP: propeller.prop; SU2: su2.cfg). It is the file the recorded staged config names whenever it exists at staging. A descriptor such as QPROP's sections.plan (the plan of section polars) is recorded in its place only for a point whose polars are computed at execution; staging itself refuses such a point, so it never reaches a cluster job without propeller.prop. |
JOB_OUTPUTS |
The declared outputs a cluster job writes. |
job_command(point) |
Optional. The command line, as a list, that a --batch script runs in the point folder (SU2: the launcher, the executable as stated, su2.cfg). An adapter without it can be grouped only for rows that state hpc.application_id. |
SOLVER_TYPE |
The solver's name as a cluster profile spells it, when it differs from the registered name. |
EXECUTABLE_KEYS |
The adapter's own [solver] option names for the executable path and the launcher. |
BUILD_OPTIONS |
Fixed [solver] options that apply when a build is bound. |
C-45. An adapter that provides stage also provides STAGED_CONFIG.
C-46. stage refuses an existing point folder and runs no solver. A
staging failure is raised as ValueError or OSError; the point is recorded
as failed and nothing is submitted.
C-47. JOB_OUTPUTS names the files, among the declared outputs, that a
cluster job writes. collect reads a submitted point once those files exist
and classifies it from them alone.
C-48. An adapter never submits a job and never names a scheduler option.
The descriptor and the submit command belong to the profile in inputs/hpc/.
C-49. An adapter whose [solver] options are not named executable and
launcher provides EXECUTABLE_KEYS, so that a row's SOLVER_BUILD selects
its executable like every other adapter's.
What an adapter leaves to the core¶
C-50. The adapter never names a point folder. It receives
point.point.directory, which the core derives from the flight condition.
C-51. The adapter never reads or writes runs.json, the plan receipt or
anything under post/.
C-52. A point folder may be moved to archive/ when the point is redone.
Whatever the adapter leaves in it (a mesh link above all) must still resolve
after the move, which is why links are relative.
C-53. The adapter writes no campaign table. The names of the coefficients it returns become column names, so a name holds no comma, quote or line break.
C-54. cfd-workspace init --solver <name> creates a workspace the adapter
can plan in: every input folder it reads exists.
Physical meaning¶
C-55. Neutral quantities are in SI units: meters, square meters, kelvin,
pascals, kilograms per cubic meter, pascal seconds, meters per second. Angles
are in degrees. A matrix key carries its unit in its name (ALTFT is feet,
REmi is millions) and the core converts it; an adapter that hands a value
to a solver in another unit converts it explicitly.
C-56. The Reynolds number of a point is based on the reference length of
the r file, or on the fixed length the adapter states (unit chord for XFOIL
and PyFR). The adapter's documentation states the direction of positive
ALPHA and BETA in its axis system.
Optional capability declarations¶
C-57. An adapter declares optional behaviors with a module attribute
CAPABILITIES = frozenset({...}). The closed vocabulary lives in
cfdbender.core.adapter.CAPABILITIES: restart, unsteady,
boundary_groups (per-boundary force groups), cluster_staging and numerics_file
(the adapter reads the NUMERICS column).
The core reader capabilities(adapter) returns the declaration; a missing
attribute means none. The registry validates it when loading the adapter.
An unknown name or a declaration other than a frozenset of names is a
developer error, refused with the known names listed.
Declare only behaviors the adapter implements today. PyFR's time marching
counts as unsteady, even though its matrix WORKFLOW is steady (the product
is a time-averaged force). unsteady means the adapter reads the time window keys of the
setup file: a time-accurate run type selected in the matrix, as SU2 offers, is not this
capability. An adapter with cluster_staging supplies stage
and STAGED_CONFIG under C-45. See
What each solver supports.
test_p051_f3c_each_declared_capability checks every capability for every
adapter; test_p051_f3c_unknown_capability_refused_at_load checks the load
refusal, and test_p051_f3c_documented_capabilities_match_declarations keeps
the documentation table aligned with the declarations.
When a cluster profile is selected, plan and run --no-local consult
cluster_staging. If absent, one warning names the solver, the capability and
the skipped staging and submission. The command continues successfully without
submitting or falling back to a local solver run. Existing input validation
still applies. A downgraded plan checks local builds and executables, and a
skipped run prints the complete local command to type.
C-58. Adapters declaring restart expose restart_files(point), which
returns point-local destination names mapped to recorded solution paths. They
refuse a missing solution with its source point named and copy those bytes
during the same staging routine used locally and on a cluster. The core checks
the source before recording or archiving and stores restart_from,
restart_directory and restart_sha256 with the point proposal. A RESTART
entry or run --restart for another adapter warns and skips through the core
refusal helper. The restart tests cover both forms for every supporting adapter.
C-59. Adapters declaring boundary_groups validate the setup [groups]
table against the mesh's named markers and return NeutralResult.force_groups.
Each named group and TOTAL holds a coefficient mapping with the result's
reference values. Collect serializes it into the campaign summary. Native files
needed to read each force set are declared outputs and, for cluster jobs, job
outputs. Group CSV products are not part of the adapter contract. The group
tests cover both supporting adapters and unknown-marker diagnostics.
Product declarations¶
The PPROC file's [sections], [volume_section] (or the provisional [[volume_sections]], supplied wherever volume_section is) and [[probes]] are read by the
core (cfdbender.core.pproc) with pyflightstream's keys; the products are computed
and written by the core and cfdbender.post. An adapter only says what it supplies.
C-60. An adapter that supplies the files a product is written from declares a
module attribute PRODUCTS, product table name to
cfdbender.core.contract.ProductSupport: the source (surface, a surface file
with connectivity, the wall families and point fields; or volume, a volume file
with connectivity and point fields), columns (each product column it fills, mapped
to its field name in the file or to a callable on the fields and the point's free
stream; for a surface, pressure is the static pressure every load is integrated
from, and an optional shear, the wall shear stress vector in Pa, makes the
sectional loads totals with their pressure and friction parts) and unfillable (each product column it cannot fill, with the reason).
product_support(adapter) reads and validates it; none declared means none
supplied. validate_row.post_products names the tables planning keeps; a table the
adapter does not supply is warned once and skipped. A column the adapter cannot fill
is absent from the product file and named under absent_columns in products.json.
SU2 and the mock adapter declare all three products.
C-61. An adapter declaring PRODUCTS exposes product_inputs(point) returning
cfdbender.core.contract.ProductInputs for a recorded point: the surface and volume
files present, one per step in step order (step None for a steady point), with
each missing file named with its reason; the free stream of the Cp columns
(p_inf, q_ref and the rule that gave them); the sign of the surface normal; the
family (marker) names of the surface file and whether the file says which cell is
of which; the solver iteration of a steady point's files; and the clock of a
time-accurate point. The adapter also asks its solver for those files, and only
when a declared product needs them. The tests of the declarations run every product
through the mock adapter.
Proving an adapter¶
cfdbender.testing provides one assertion per group of clauses. Each takes
the adapter and a freshly prepared case; none imports or launches a solver by
itself, so the adapter's tests supply a stand-in executable.
| Assertion | Clauses |
|---|---|
assert_reads_init(adapter, point) |
C-19 |
assert_validation(adapter, row, workspace, problem) |
C-08, C-16 |
assert_deterministic(adapter, point) |
C-18 |
assert_classifications(adapter, cases) |
C-23, C-31, C-35 |
assert_exit_evidence(adapter, point) |
C-32 |
assert_results(adapter, point) |
C-37 |
assert_no_overwrite(adapter, point) |
C-22 |
assert_execution_isolation(adapter, point) |
C-21 |
assert_run_record(adapter, plan) |
C-10 |
assert_finished_no_overwrite(adapter, plan) |
C-22 |
assert_collected_results(adapter, plan) |
C-36, C-37 |
from cfdbender import testing
from cfdbender.core.adapter import load_point
from cfdbender.solvers import load_solver
from cfdbender.workspace.planning import plan_workspace
adapter = load_solver("mysolver")
plan = plan_workspace(root, "study")
point = load_point(root, plan.points[0], solver="mysolver")
testing.assert_deterministic(adapter, point)
Adding a solver¶
- Create
src/cfdbender/solvers/<name>/with the five functions and a module docstring that says what the s, r and p files hold, how the executable is chosen, whatconvergedmeans and which references and axes the result carries. - Register the name in
cfdbender.solvers. - Add the name to the solvers that get the short input layout in
cfdbender.core.workspace, unless it needs the full one. - Reuse
cfdbender.solvers._hostfor the memory guard, the process lease, the timeout, the process cleanup and the mesh link. - Write a stand-in executable for the offline tests and add the adapter to the conformance suite and to the all-solvers matrix test.
- Add
docs/<name>-workspaces.mdand its navigation entry. - Run the gates listed in
CONTRIBUTING.md.
The OpenFOAM force-table reader accepts Time in any header position, as required by C-41; the shared reorder test covers it.